Repeatability of apparent diffusion coefficient and intravoxel incoherent motion parameters at 3.0 Tesla in orbital lesions.

Objectives: To evaluate repeatability of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters in the orbit.Methods: From December 2015 to March 2016, 22 patients were scanned twice using an IVIM sequence with 15b values (0-2,000 s/mm2) at 3.0T. Two readers independently de...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 27; no. 12; pp. 5094 - 5104
Autores principales: Lecler, Augustin, Savatovsky, Julien, Balvay, Daniel, Zmuda, Mathieu, Sadik, Jean-Claude, Galatoire, Olivier, Charbonneau, Frédérique, Bergès, Olivier, Picard, Hervé, Fournier, Laure
Formato: Journal Article
Publicado: Springer Nature Dec2017
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=126091237&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 126091237
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Dec2017
      vid: 27
      iid: 12
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        126091237
        126091237
        144046068
        NLM28677061
        10.1007/s00330-017-4933-6
        NLM28677061
        126091237
      ppf: 5094
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Repeatability of apparent diffusion coefficient and intravoxel incoherent motion parameters at 3.0 Tesla in orbital lesions.
      aug:
        au:
          Lecler, Augustin
          Savatovsky, Julien
          Balvay, Daniel
          Zmuda, Mathieu
          Sadik, Jean-Claude
          Galatoire, Olivier
          Charbonneau, Frédérique
          Bergès, Olivier
          Picard, Hervé
          Fournier, Laure
          Charbonneau, Frédérique
          Bergès, Olivier
          Picard, Hervé
        affil: Department of Radiology , Fondation Ophtalmologique Adolphe de Rothschild , 29 rue Manin 75019 Paris France
      sug:
        subj:
          Magnetic Resonance Imaging Methods
          Orbital Neoplasms
          Female
          Middle Age
          Observer Bias
          Male
          Reproducibility of Results
          Prospective Studies
          Motion
          Adult
          Short Portable Mental Status Questionnaire
          Middle Aged: 45-64 years
          Adult: 19-44 years
          Female
          Male
      ab: Objectives: To evaluate repeatability of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters in the orbit.Methods: From December 2015 to March 2016, 22 patients were scanned twice using an IVIM sequence with 15b values (0-2,000 s/mm2) at 3.0T. Two readers independently delineated regions of interest in an orbital mass and in different intra-orbital and extra-orbital structures. Short-term test-retest repeatability and inter-observer agreement were assessed using the intra-class correlation coefficient (ICC), the coefficient of variation (CV) and Bland-Altman limits of agreements (BA-LA).Results: Test-retest repeatability of IVIM parameters in the orbital mass was satisfactory for ADC and D (mean CV 12% and 14%, ICC 95% and 93%), poor for f and D*(means CV 43% and 110%, ICC 90% and 65%). Inter-observer repeatability agreement was almost perfect in the orbital mass for all the IVIM parameters (ICC = 95%, 93%, 94% and 90% for ADC, D, f and D*, respectively).Conclusions: IVIM appeared to be a robust tool to measure D in orbital lesions with good repeatability, but this approach showed a poor repeatability of f and D*.Key Points: • IVIM technique is feasible in the orbit. • IVIM has a good-acceptable repeatability of D (CV range 12-25 %). • IVIM interobserver repeatability agreement is excellent (ICC range 90-95 %). • f or D* provide higher test-retest and interobserver variabilities.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N