Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.
The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D....
| Publicado en: | Gait & Posture Vol. 59; pp. 258 - 261 |
|---|---|
| Autores principales: | , , , , , |
| Formato: | research Journal Article |
| Publicado: |
Elsevier B.V.
Jan2018
|
| Acceso en línea: | Ver este registro en EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=126185625&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 126185625 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 09666362 3L6 jtl: Gait & Posture issn: 09666362 maglogo: N pubinfo: dt: Jan2018 vid: 59 pid: 1004 pub: Elsevier B.V. artinfo: ui: 126185625 126185625 NLM29102855 126185625 10.1016/j.gaitpost.2017.10.028 NLM29102855 126185625 ppf: 258 ppct: 3 formats: tig: atl: Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests. aug: au: Medina-Mirapeix, Francesc Vivo-Fernández, Iván López-Cañizares, Juan García-Vidal, José A. del Baño-Aledo, María Elena Benítez-Martínez, Josep Carles affil: Department of Physical Therapy, University of Murcia, Spain sug: subj: Activities of Daily Living Arthroplasty, Replacement, Knee Rehabilitation Posture Physiology Gait Physiology Adult Male Human Middle Age Aged, 80 and Over Reproducibility of Results Aged Recovery Observer Bias Female Validation Studies Comparative Studies Evaluation Research Multicenter Studies Clinical Assessment Tools Adult: 19-44 years Middle Aged: 45-64 years Aged, 80 & over Aged: 65+ years Male Female ab: The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, p<0.001) and 4MGS (r=-0.583, p=0.003). This study demonstrates excellent inter-observer and test-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. pubtype: Academic Journal doctype: research Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|