In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease.

Objectives Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometric...

Descripción completa

Detalles Bibliográficos
Publicado en:Vascular Vol. 25; no. 6; pp. 635 - 642
Autores principales: Groot Jebbink, Erik, Ter Mors, Thijs G., Slump, Cornelis H., Geelkerken, Robert H., Holewijn, Suzanne, Reijnen, Michel M. P. J., Reijnen, Michel Mpj
Formato: research Journal Article
Publicado: Sage Publications Inc. Dec2017
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=126515327&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 126515327
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        17085381
        0GN
      jtl: Vascular
      issn: 17085381
      maglogo: N
    pubinfo:
      dt: Dec2017
      vid: 25
      iid: 6
      pid: 344
      pub: Sage Publications Inc.
      place: Thousand Oaks, California
    artinfo:
      ui:
        126515327
        126515327
        NLM28530484
        126515327
        10.1177/1708538117708912
        NLM28530484
        126515327
      ppf: 635
      ppct: 7
      formats:
      tig:
        atl: In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease.
      aug:
        au:
          Groot Jebbink, Erik
          Ter Mors, Thijs G.
          Slump, Cornelis H.
          Geelkerken, Robert H.
          Holewijn, Suzanne
          Reijnen, Michel M. P. J.
          Reijnen, Michel Mpj
        affil: Department of Surgery, Rijnstate Hospital, Arnhem, The Netherlands
      sug:
        subj:
          Aortic Diseases Therapy
          Iliac Artery
          Iliac Artery Physiopathology
          Angioplasty, Balloon Equipment and Supplies
          Peripheral Vascular Diseases Therapy
          Prosthesis Design
          Netherlands
          Angioplasty, Balloon Adverse Effects
          Angiography Methods
          Male
          Aged
          Aortic Diseases
          Middle Age
          Peripheral Vascular Diseases Physiopathology
          Peripheral Vascular Diseases
          Alloys
          Human
          Aortic Diseases Physiopathology
          Treatment Outcomes
          Female
          Validation Studies
          Comparative Studies
          Evaluation Research
          Multicenter Studies
          Aged: 65+ years
          Middle Aged: 45-64 years
          Male
          Female
      ab: Objectives Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometrical mismatch of kissing stent with the covered endovascular reconstruction of the aortic bifurcation configuration in vivo. Methods Post-operative computed tomographic data and patient demographics from 11 covered endovascular reconstruction of the aortic bifurcation and 11 matched kissing stent patients were included. A free hand region of interest and ellipse fitting method were applied to determine mismatch areas and volumes. Conformation of the stents to the vessel wall was expressed using the D-ratio. Results Patients were mostly treated for Rutherford category 2 and 3 (64%) with a lesion classification of TASC C and D in 82%. Radial mismatch area and volume for the covered endovascular reconstruction of the aortic bifurcation group was significantly lower compared to the kissing stent configuration ( P < 0.05). The D-ratio did not significantly differ between groups. Measurements were performed with good intra-class correlation. There were no significant differences in the post-procedural aortoiliac anatomy. Conclusions The present study shows that radial mismatch exists in vivo and that large differences in mismatch exist, in favour of the covered endovascular reconstruction of the aortic bifurcation configuration. Future research should determine if the decreased radial mismatch results in improved local flow profiles and subsequent clinical outcome.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N