An investigation into the variability between different shear wave elastography systems in muscle.

Aims: The reliability and agreement between shear wave elastography (SWE) systems using different acquisition methods in muscles is not yet established. The objectives were to determine the reliability of a new SWE system on normal resting muscles using different acquisition methods and to compare i...

Descripción completa

Detalles Bibliográficos
Publicado en:Medical Ultrasonography Vol. 19; no. 4; pp. 392 - 401
Autores principales: Alfuraih, Abdulrahman M., O'connor, Phil, Ai Lyn Tan, Hensor, Elizabeth M. A., Emery, Paul, Wakefield, Richard J., O'Connor, Philip, Tan, Ai Lyn, Hensor, Elizabeth
Formato: Journal Article
Publicado: Romanian Society of Ultrasonography in Medicine & Biology Dec2017
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=126686546&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 126686546
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        18444172
        AX1S
      jtl: Medical Ultrasonography
      issn: 18444172
      maglogo: N
    pubinfo:
      dt: Dec2017
      vid: 19
      iid: 4
      pid: 57537
      pub: Romanian Society of Ultrasonography in Medicine & Biology
    artinfo:
      ui:
        126686546
        126686546
        NLM29197916
        10.11152/mu-1113
        NLM29197916
        126686546
      ppf: 392
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: An investigation into the variability between different shear wave elastography systems in muscle.
      aug:
        au:
          Alfuraih, Abdulrahman M.
          O'connor, Phil
          Ai Lyn Tan
          Hensor, Elizabeth M. A.
          Emery, Paul
          Wakefield, Richard J.
          O'Connor, Philip
          Tan, Ai Lyn
          Hensor, Elizabeth
        affil: Radiology and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Kharj, Saudi Arabia
      sug:
        subj:
          Muscle, Skeletal Anatomy and Histology
          Ultrasonography Methods
          Reproducibility of Results
          Adult
          Female
          Male
          Reference Values
          Arthritis Impact Measurement Scales
          Adult: 19-44 years
          Female
          Male
      ab: Aims: The reliability and agreement between shear wave elastography (SWE) systems using different acquisition methods in muscles is not yet established. The objectives were to determine the reliability of a new SWE system on normal resting muscles using different acquisition methods and to compare its performance to an established state-of-the-art system.Materials and Methods: Small, medium and large ROI sizes in addition to longitudinal, oblique and transverse orientations over five different locations within the rectus femoris muscle were tested using the new system. Results were compared to the established system to test for inter-system reproducibility.Results: Lowest within-subject coefficient of variance (4.3%) andshear wave velocity (1.83 m/s) were associated with the medium ROI and longitudinal orientation from the lateral location. This combination resulted in a strong internal agreement of intra-class correlation of 0.76 (0.57-0.89) for the new system and an almost perfect agreement of 0.92 (0.82-0.97) for the established. Inter-system reproducibility for the best combination was 0.71 (0.48-1) with a mean velocity difference ±95% limits of agreement of 0.07±0.49 m/s.Conclusions: Altering SWE acquisition methods can produce variable results. The new system produced reliable results that are comparable with but not as reliable as the established.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N