Comparación de dos Sistemas de Captura de Movimiento por medio de las Trayectorias Articulares de Marcha.

Currently, the most common methods for proper capture of human movement in three dimensions require a laboratory environment and setting markers, accessories or sensors to the body segments. However, the high cost of this equipment is a limiting factor in diverse environments. Motion capture systems...

Descripción completa

Detalles Bibliográficos
Publicado en:Revista Mexicana de Ingeniería Biomédica Vol. 37; no. 2; pp. 149 - 161
Autores principales: Bravo M., D. A., Rengifo R., C. F., Agredo R., W.
Formato: Artículo
Publicado: Sociedad Mexicana de Ingenieria Biomedica, A.C. May-Ago2016
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=126949765&site=ehost-live
header:
  @attributes:
    shortDbName: lth
    uiTerm: 126949765
    longDbName: MedicLatina
    uiTag: AN
  controlInfo:
    bkinfo:
    jinfo:
      jid:
        01889532
        7L3
      jtl: Revista Mexicana de Ingeniería Biomédica
      issn: 01889532
      maglogo: N
    pubinfo:
      dt: May-Ago2016
      vid: 37
      iid: 2
      pid: 20850
      pub: Sociedad Mexicana de Ingenieria Biomedica, A.C.
    artinfo:
      ui:
        126949765
        10.17488/RMIB.37.2.2
      ppf: 149
      ppct: 12
      formats:
        fmt:
          @attributes:
            type: P
            size: 3MB
      tig:
        atl: Comparación de dos Sistemas de Captura de Movimiento por medio de las Trayectorias Articulares de Marcha.
      aug:
        au:
          Bravo M., D. A.
          Rengifo R., C. F.
          Agredo R., W.
        affil:
          Departamento de Física, Universidad del Cauca, Calle 5 No. 4-70, Popayán, Colombia
          Departamento de Electrónica, Instrumentación y Control, Universidad del Cauca, Calle 5 No. 4-70, Popayán, Colombia
          Laboratorio de Biomecánica, Universidad Autónoma de Occidente, Calle 25 No. 115-85. Cali, Colombia
      sug:
      keyword:
        biomechanics
        human gait
        joint trajectories
        motion capture
        biomecánica
        captura de movimiento
        marcha humana
        Microsoft Kinect™
        trayectorias articulares
      ab:
        Currently, the most common methods for proper capture of human movement in three dimensions require a laboratory environment and setting markers, accessories or sensors to the body segments. However, the high cost of this equipment is a limiting factor in diverse environments. Motion capture systems such as Microsoft Kinect™present an alternative approach to motion capture technology. In this paper, two motion capture systems are compared by means of joint trajectories and anthropometric measurements of a person in a normal gait cycle. The first is accurate trading system that uses markers (Vicon™), and the second is Microsoft Kinect™ camera. Both systems were evaluated in order to compare the geometric difference and the RMS error between the joint human walking paths obtained for each of the systems. The results show a greater variance in anthropometric measures and joint trajectories for Kinect, although this system is inexpensive and easy to use and install, cannot be used for precise kinematic analysis of human walking.
        En la actualidad, los métodos más comunes para una adecuada captura del movimiento humano en tres dimensiones requieren de un entorno de laboratorio y la fijación de marcadores, accesorios o sensores a los segmentos corporales. Sin embargo, el alto costo de estos equipos es un factor limitante en diversos entornos de trabajo. Sistemas de captura de movimiento como Microsoft Kinect ™presentan un enfoque alternativo a la tecnología de captura de movimiento. En este trabajo se comparan dos sistemas de captura de movimiento por medio de las trayectorias articulares y las medidas antropométricas de una persona en un ciclo de marcha normal. El primero de ellos, es un sistema comercial de precisión que utiliza marcadores (Vicon ™) y el segundo, es la cámara Microsoft Kinect™. Ambos sistemas se evaluaron con el propósito de comparar la diferencia geométrica y el error RMS entre las trayectorias articulares de la marcha humana obtenidas por cada uno de los sistemas. Los resultados muestran una varianza mayor en las medidas antropométricas y trayectorias articulares para el Kinect, aunque este sistema es de bajo costo y de fácil uso e instalación, no puede ser utilizado para un análisis preciso de la cinemática de la marcha humana.
      pubtype: Academic Journal
      doctype: Article
      src: R
    language: Spanish
    refInfo:
    copyright:
      @attributes:
        flag: Y
      custom: Copyright of Revista Mexicana de Ingeniería Biomédica is the property of Sociedad Mexicana de Ingenieria Biomedica, A.C. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use.
      item: Revista Mexicana de Ingeniería Biomédica
      holder: Sociedad Mexicana de Ingenieria Biomedica, A.C.
      dt:
        @attributes:
          year: 2016
    holdings:
      @attributes:
        islocal: N