Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices.

Background: Patients who have pacemakers or defibrillators are often denied the opportunity to undergo magnetic resonance imaging (MRI) because of safety concerns, unless the devices meet certain criteria specified by the Food and Drug Administration (termed "MRI-conditional" devices).Methods: We pe...

Full description

Bibliographic Details
Published in:New England Journal of Medicine Vol. 377; no. 26; pp. 2555 - 2565
Main Authors: Nazarian, Saman, Hansford, Rozann, Rahsepar, Amir A., Weltin, Valeria, McVeigh, Diana, Ipek, Esra Gucuk, Kwan, Alan, Berger, Ronald D., Calkins, Hugh, Lardo, Albert C., Kraut, Michael A., Kamel, Ihab R., Zimmerman, Stefan L., Halperin, Henry R., Gucuk Ipek, Esra
Format: research tables/charts Journal Article
Published: New England Journal of Medicine 12/28/2017
Online Access:View this record in EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=127015492&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 127015492
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00284793
        NEJ
      jtl: New England Journal of Medicine
      issn: 00284793
      maglogo: N
    pubinfo:
      dt: 12/28/2017
      vid: 377
      iid: 26
      pid: 388
      pub: New England Journal of Medicine
      place: Waltham, Massachusetts
    artinfo:
      ui:
        127015492
        127015492
        NLM29281579
        127015492
        10.1056/NEJMoa1604267
        NLM29281579
        127015492
      ppf: 2555
      ppct: 10
      formats:
      tig:
        atl: Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices.
      aug:
        au:
          Nazarian, Saman
          Hansford, Rozann
          Rahsepar, Amir A.
          Weltin, Valeria
          McVeigh, Diana
          Ipek, Esra Gucuk
          Kwan, Alan
          Berger, Ronald D.
          Calkins, Hugh
          Lardo, Albert C.
          Kraut, Michael A.
          Kamel, Ihab R.
          Zimmerman, Stefan L.
          Halperin, Henry R.
          Gucuk Ipek, Esra
        affil: Department of Medicine-Cardiology,University of Pennsylvania PerelmanSchool of Medicine, Philadelphia
      sug:
        subj:
          Equipment Safety
          Pacemaker, Artificial
          Defibrillators, Implantable
          Magnetic Resonance Imaging Adverse Effects
          Male
          Female
          Middle Age
          Prospective Studies
          Power Sources
          Aged
          Equipment Failure
          Funding Source
          Human
          Middle Aged: 45-64 years
          Aged: 65+ years
          Male
          Female
      ab: Background: Patients who have pacemakers or defibrillators are often denied the opportunity to undergo magnetic resonance imaging (MRI) because of safety concerns, unless the devices meet certain criteria specified by the Food and Drug Administration (termed "MRI-conditional" devices).Methods: We performed a prospective, nonrandomized study to assess the safety of MRI at a magnetic field strength of 1.5 Tesla in 1509 patients who had a pacemaker (58%) or an implantable cardioverter-defibrillator (42%) that was not considered to be MRI-conditional (termed a "legacy" device). Overall, the patients underwent 2103 thoracic and nonthoracic MRI examinations that were deemed to be clinically necessary. The pacing mode was changed to asynchronous mode for pacing-dependent patients and to demand mode for other patients. Tachyarrhythmia functions were disabled. Outcome assessments included adverse events and changes in the variables that indicate lead and generator function and interaction with surrounding tissue (device parameters).Results: No long-term clinically significant adverse events were reported. In nine MRI examinations (0.4%; 95% confidence interval, 0.2 to 0.7), the patient's device reset to a backup mode. The reset was transient in eight of the nine examinations. In one case, a pacemaker with less than 1 month left of battery life reset to ventricular inhibited pacing and could not be reprogrammed; the device was subsequently replaced. The most common notable change in device parameters (>50% change from baseline) immediately after MRI was a decrease in P-wave amplitude, which occurred in 1% of the patients. At long-term follow-up (results of which were available for 63% of the patients), the most common notable changes from baseline were decreases in P-wave amplitude (in 4% of the patients), increases in atrial capture threshold (4%), increases in right ventricular capture threshold (4%), and increases in left ventricular capture threshold (3%). The observed changes in lead parameters were not clinically significant and did not require device revision or reprogramming.Conclusions: We evaluated the safety of MRI, performed with the use of a prespecified safety protocol, in 1509 patients who had a legacy pacemaker or a legacy implantable cardioverter-defibrillator system. No long-term clinically significant adverse events were reported. (Funded by Johns Hopkins University and the National Institutes of Health; ClinicalTrials.gov number, NCT01130896 .).
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N