Measurements Obtained From Esophageal Balloon Catheters Are Affected by the Esophageal Balloon Filling Volume in Children With ARDS.

BACKGROUND: Esophageal balloon inflation volume may affect the accuracy of transpulmonary pressure estimates in adults, but the effect is unknown in pediatrics. Using a combination bench and human study, we sought to determine a range of optimal filling volumes for esophageal balloon catheters and t...

Descripción completa

Detalles Bibliográficos
Publicado en:Respiratory Care Vol. 63; no. 2; pp. 177 - 187
Autores principales: Hotz, Justin C., Sodetani, Cary T., Van Steenbergen, Jeffrey, Khemani, Robinder G., Deakers, Timothy W., Newth, Christopher J.
Formato: research tables/charts Journal Article
Publicado: Mary Ann Liebert, Inc. Feb2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=127544997&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 127544997
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00201324
        4GG
      jtl: Respiratory Care
      issn: 00201324
      maglogo: N
    pubinfo:
      dt: Feb2018
      vid: 63
      iid: 2
      pid: 1365
      pub: Mary Ann Liebert, Inc.
      place: New Rochelle, New York
    artinfo:
      ui:
        127544997
        127544997
        127544997
        10.4187/respcare.05685
        127544997
      ppf: 177
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Measurements Obtained From Esophageal Balloon Catheters Are Affected by the Esophageal Balloon Filling Volume in Children With ARDS.
      aug:
        au:
          Hotz, Justin C.
          Sodetani, Cary T.
          Van Steenbergen, Jeffrey
          Khemani, Robinder G.
          Deakers, Timothy W.
          Newth, Christopher J.
        affil: Department of Respiratory Care, Children's Hospital Los Angeles, CA
      sug:
        subj:
          Balloon Dilatation
          Esophagus
          Human
          Child
          Adult
          Laboratories
          Comparative Studies
          Respiratory Distress Syndrome, Acute
          Funding Source
          Child: 6-12 years
          Adult: 19-44 years
      ab: BACKGROUND: Esophageal balloon inflation volume may affect the accuracy of transpulmonary pressure estimates in adults, but the effect is unknown in pediatrics. Using a combination bench and human study, we sought to determine a range of optimal filling volumes for esophageal balloon catheters and to derive a technique to inflate catheters to yield the most accurate estimates of pleural pressure. METHODS: In the laboratory study, we evaluated 4 pediatric and adult esophageal balloon catheters, a liquid-filled catheter, and a micro-tip catheter, both with and without a model esophagus. We compared the measured esophageal pressure for each type of catheter within a pressurized chamber. Esophageal balloon catheters were also tested by manipulating the esophageal balloon inflation volume, and we attempted to derive a filling-volume technique that would assure accuracy. We then tested the feasibility of this technique in 5 mechanically ventilated pediatric subjects with ARDS. RESULTS: In the laboratory study, smaller inflation volumes underestimated the chamber pressure at higher chamber pressures, and larger inflation volumes overestimated the chamber pressure at lower chamber pressures. Using an optimal filling-volume technique resulted in a mean total error that ranged from -0.53 to -0.10 cm H2O. The optimal filling-volume values for the pediatric catheters were 0.2-0.6 mL, and 0.4-0.8 mL for the adult catheters. When correctly positioned and calibrated, the micro-tip transducer and liquid-filled catheters were within ± 1 cm H2O of chamber pressure for all ranges of pressure. In the clinical study, high variability in measured esophageal pressure and subsequent transpulmonary pressure during exhalation and during inhalation was observed within the manufacturer's recommended esophageal balloon inflation ranges. CONCLUSIONS: Manufacturer-recommended esophageal balloon inflation ranges do not assure accuracy. Individual titration of esophageal balloon volume may improve accuracy. Better esophageal catheters are needed to provide reliable esophageal pressure measurements in children.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N