Low‐fidelity simulation for patients and caregivers in the use of lubricants in clean intermittent catheterization.

ABSTRACT: Can low‐fidelity simulation improve the knowledge and skills of patients undergoing clean intermittent catheterization (CIC) and their caregivers to prevent complications? Patients undergoing CIC are exposed to risks, such as urethral trauma and urinary tract infections. Objective of this...

Descripción completa

Detalles Bibliográficos
Publicado en:International Journal of Urological Nursing Vol. 12; no. 1; pp. 9 - 16
Autores principales: Orlandin, Leonardo, Mazzo, Alessandra, Meska, Mateus Henrique Gonçalves, Jorge, Beatriz Maria, Cotta Filho, Cezar Kayzuka, Fumincelli, Laís
Formato: research tables/charts Journal Article
Publicado: Wiley-Blackwell Mar2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=128036660&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 128036660
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        17497701
        30RG
      jtl: International Journal of Urological Nursing
      issn: 17497701
      maglogo: Y
    pubinfo:
      dt: Mar2018
      vid: 12
      iid: 1
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        128036660
        128036660
        128036660
        10.1111/ijun.12155
        128036660
      ppf: 9
      ppct: 7
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Low‐fidelity simulation for patients and caregivers in the use of lubricants in clean intermittent catheterization.
      aug:
        au:
          Orlandin, Leonardo
          Mazzo, Alessandra
          Meska, Mateus Henrique Gonçalves
          Jorge, Beatriz Maria
          Cotta Filho, Cezar Kayzuka
          Fumincelli, Laís
        affil: Teaching Diploma student, University of São Paulo at Ribeirão Preto College of Nursing, São Paulo, Brazil
      sug:
        subj:
          Simulations
          Lubricants
          Caregivers Education
          Urinary Catheterization, Intermittent Education
          Human
          Quasi-Experimental Studies
          Semi-Structured Interview
          Observational Methods
          Pretest-Posttest Design
          Male
          Female
          Adult
          Brazil
          Paired T-Tests
          Pearson's Correlation Coefficient
          Chi Square Test
          Fisher's Exact Test
          Data Analysis Software
          Hemorrhage
          P-Value
          Adult: 19-44 years
          Male
          Female
      ab: ABSTRACT: Can low‐fidelity simulation improve the knowledge and skills of patients undergoing clean intermittent catheterization (CIC) and their caregivers to prevent complications? Patients undergoing CIC are exposed to risks, such as urethral trauma and urinary tract infections. Objective of this paper was to assess the implications of low‐fidelity simulations for patients and caregivers in the use of clean intermittent catheterization in the event of urethral trauma and for its prevention. A quasi‐experimental study carried out between November 2015 and February 2016 in the rehabilitation centre of a university hospital, with patients undergoing CIC and/or their caregivers. Following the ethical precepts, data collection was performed during nursing consultations by means of interviews, structured observation, and a knowledge test applied before and after the low‐fidelity simulation. Patients undergoing CIC and/or caregivers underwent a low‐fidelity simulation of CIC with urethral trauma and then they were guided by the researchers following the protocol established in the department. They then underwent another simulation with the same characteristics. Fifty‐five patients participated in this study, in which most of them (33 [60·0%]) were men, with an average age of 31·7 years. Bleeding was reported by 19 patients (34·5%), of which 18 were men. The performance of low‐fidelity simulations proved to be effective for patients or caregivers in adverse situations, such as bleeding, resistance to the introduction of the catheter and negative urine drainage. The performance of low‐fidelity simulation is easily accessible and shows efficiency when used in teaching‐learning processes of health education and development of skills and competencies.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N