Elastografía en tiempo real (supersonic): comportamiento de la prueba en sujetos sanos de Bogotá.

Introduction: Real-time supersonic shear wave elastography (SSI) is a noninvasive test that is used to determine the elasticity of the liver and thus calculate the degree of liver fibrosis. Sometimes, it can replace a liver biopsy, and it is useful for monitoring the majority of patients with liver...

Descripción completa

Detalles Bibliográficos
Publicado en:Revista Colombiana de Gastroenterología Vol. 32; no. 4; pp. 332 - 337
Autores principales: Prieto O., Jhon E., Sánchez P., Santiago, Prieto O., Robin G., Garzón-Orjuela, Nathaly, Eslava-Schmalbach, Javier
Formato: Artículo
Publicado: Asociacion Colombiana de Gastroenterologia oct-dic2017
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=128173082&site=ehost-live
header:
  @attributes:
    shortDbName: lth
    uiTerm: 128173082
    longDbName: MedicLatina
    uiTag: AN
  controlInfo:
    bkinfo:
    jinfo:
      jid:
        01209957
        78D5
      jtl: Revista Colombiana de Gastroenterología
      issn: 01209957
      maglogo: N
    pubinfo:
      dt: oct-dic2017
      vid: 32
      iid: 4
      pid: 47611
      pub: Asociacion Colombiana de Gastroenterologia
    artinfo:
      ui:
        128173082
        10.22516/25007440.176
      ppf: 332
      ppct: 5
      formats:
        fmt:
          @attributes:
            type: P
            size: 364KB
      tig:
        atl: Elastografía en tiempo real (supersonic): comportamiento de la prueba en sujetos sanos de Bogotá.
      aug:
        au:
          Prieto O., Jhon E.
          Sánchez P., Santiago
          Prieto O., Robin G.
          Garzón-Orjuela, Nathaly
          Eslava-Schmalbach, Javier
        affil:
          Centro De Enfermedades Hepáticas y Digestivas (CEHYD), Bogotá, Colombia
          Universidad Industrial de Santander, Bucaramanga, Colombia
          Hospital Universitario Nacional De Colombia, Grupo Equidad en Salud, Facultad de Medicina, Universidad Nacional de Colombia, Bogotá, Colombia
      sug:
      keyword:
        healthy adults
        hepatic fibrosis
        Real-time elastography
        adultos sanos
        Elastografía en tiempo real
        fibrosis hepática
        supersonic
      ab:
        Introduction: Real-time supersonic shear wave elastography (SSI) is a noninvasive test that is used to determine the elasticity of the liver and thus calculate the degree of liver fibrosis. Sometimes, it can replace a liver biopsy, and it is useful for monitoring the majority of patients with liver disease. In Colombia, the test has recently been introduced, so there have been no studies of test in healthy people here until now. Objective: The objective of this study was to evaluate the behavior of the elastography in real time in healthy subjects in Bogotá. Materials and methods: This is a retrospective pilot study of healthy subjects between 15 and 37 years old who underwent SSI between June 1, 2016 and March 31, 2017. A clinical history was taken and basic evaluation of liver function was performed to rule out abnormalities. Results: The series included 33 healthy subjects, 60.6% women and 39.4% men with an average age of 24.8 years. When the test was performed, an average value of 4.28 kilopascals (kPs) was found, with minimal difference between the sexes but greater hepatic rigidity in men. Conclusions: The mean values of hepatic rigidity in 33 healthy subjects in Bogotá are the same as those reported in the initial studies internationally. These findings suggest that the test may be very useful for the evaluation of patients with liver disease in our environment.
        Introducción: La elastografía en tiempo real (supersonic) es una prueba no invasiva que se utiliza para determinar la elasticidad del hígado y de esa forma calcular el grado de fibrosis hepática; en algunas ocasiones, reemplaza la toma de la biopsia hepática y es útil para el seguimiento de la mayoría de pacientes con hepatopatías. En Colombia, la prueba se introdujo recientemente y no existen hasta el momento estudios del comportamiento de la prueba en personas sanas. Objetivo: evaluar el comportamiento de la elastografía en tiempo real en sujetos sanos en Bogotá. Materiales y métodos: estudio piloto retrospectivo de sujetos sanos entre 15 y 37 años, entre el 1 de junio de 2016 y el 31 de marzo del 2017. Se realizaron la historia clínica y evaluación básica de la función hepática para descartar anormalidades. Resultados: la serie incluyó 33 sujetos sanos, 60,6% mujeres y 39,4% hombres con una edad promedio de 24,8 años. Al practicar la prueba se encontró un valor promedio de 4,28 kilopascales (kPa), con una diferencia mínima entre sexos, siendo mayor la rigidez hepática en los hombres. Conclusiones: los valores promedio de la rigidez hepática en 33 sujetos sanos en Bogotá son los mismos reportados en los estudios iniciales de las pruebas a nivel internacional; estos hallazgos sugieren que la prueba puede ser muy útil en nuestro medio para la evaluación de pacientes con hepatopatías.
      pubtype: Academic Journal
      doctype: Article
      src: R
    language: Spanish
    refInfo:
    copyright:
      @attributes:
        flag: Y
      custom: Copyright of Revista Colombiana de Gastroenterología is the property of Asociacion Colombiana de Gastroenterologia and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use.
      item: Revista Colombiana de Gastroenterología
      holder: Asociacion Colombiana de Gastroenterologia
      dt:
        @attributes:
          year: 2017
    holdings:
      @attributes:
        islocal: N