Validation of goose liver fat measurement by QCT and CSE-MRI with biochemical extraction and pathology as reference.

Objectives: This study aimed to validate the accuracy and reliability of quantitative computed tomography (QCT) and chemical shift encoded magnetic resonance imaging (CSE-MRI) to assess hepatic steatosis.Methods: Twenty-two geese with a wide range of hepatic steatosis were collected. After QCT and C...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 28; no. 5; pp. 2003 - 2013
Autores principales: Xu, Li, Duanmu, Yangyang, Blake, Glen M., Zhang, Chenxin, Zhang, Yong, Brown, Keenan, Wang, Xiaoqi, Wang, Peng, Zhou, Xingang, Zhang, Manling, Wang, Chao, Guo, Zhe, Guglielmi, Giuseppe, Cheng, Xiaoguang
Formato: research Journal Article
Publicado: Springer Nature May2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=128864708&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 128864708
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: May2018
      vid: 28
      iid: 5
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        128864708
        128864708
        NLM29238866
        128864708
        10.1007/s00330-017-5189-x
        NLM29238866
        128864708
      ppf: 2003
      ppct: 10
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Validation of goose liver fat measurement by QCT and CSE-MRI with biochemical extraction and pathology as reference.
      aug:
        au:
          Xu, Li
          Duanmu, Yangyang
          Blake, Glen M.
          Zhang, Chenxin
          Zhang, Yong
          Brown, Keenan
          Wang, Xiaoqi
          Wang, Peng
          Zhou, Xingang
          Zhang, Manling
          Wang, Chao
          Guo, Zhe
          Guglielmi, Giuseppe
          Cheng, Xiaoguang
        affil: Department of Radiology, Beijing Jishuitan Hospital, 31 Xinjiekou East Street, 100035, Beijing, China
      sug:
        subj:
          Fatty Liver
          Magnetic Resonance Imaging Methods
          Tomography, X-Ray Computed Methods
          Animal Studies
          Human
          Liver
          Poultry
          Models, Biological
          Male
          Liver Pathology
          Fatty Liver Pathology
          Female
          Reproducibility of Results
          Validation Studies
          Comparative Studies
          Evaluation Research
          Multicenter Studies
          Funding Source
          Male
          Female
      ab: Objectives: This study aimed to validate the accuracy and reliability of quantitative computed tomography (QCT) and chemical shift encoded magnetic resonance imaging (CSE-MRI) to assess hepatic steatosis.Methods: Twenty-two geese with a wide range of hepatic steatosis were collected. After QCT and CSE-MRI examinations, the liver of each goose was removed and samples were taken from the left lobe, upper and lower half of the right lobe for biochemical measurement and histology. Fat percentages by QCT and proton density fat fraction by MRI (MRI-PDFF) were measured within the sample regions of biochemical measurement and histology. The accuracy of QCT and MR measurements were assessed through Spearman correlation coefficients (r) and Passing and Bablok regression equations using biochemical measurement as the "gold standard".Results: Both QCT and MRI correlated highly with chemical extraction [r = 0.922 (p < 0.001) and r = 0.949 (p < 0.001) respectively]. Chemically extracted triglyceride was accurately predicted by both QCT liver fat percentages (Y = 0.6 + 0.866 × X) and by MRI-PDFF (Y = -1.8 + 0.773 × X).Conclusions: QCT and CSE-MRI measurements of goose liver fat were accurate and reliable compared with biochemical measurement.Key Points: • QCT and CSE-MRI can measure liver fat content accurately and reliably • Histological grading of hepatic steatosis has larger sampling variability • QCT and CSE-MRI have potential in the clinical setting.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N