Computational wear assessment of hard on hard hip implants subject to physically demanding tasks.

Hip implants subject to gait loading due to occupational activities are potentially prone to failures such as osteolysis and aseptic loosening, causing painful revision surgeries. Highly risky gait activities such as carrying a load, stairs up or down and ladder up or down may cause excessive loadin...

Descripción completa

Detalles Bibliográficos
Publicado en:Medical & Biological Engineering & Computing Vol. 56; no. 5; pp. 899 - 911
Autores principales: Nithyaprakash, R., Shankar, S., Uddin, M. S.
Formato: Journal Article
Publicado: Springer Nature May2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=129156222&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 129156222
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01400118
        PO0
      jtl: Medical & Biological Engineering & Computing
      issn: 01400118
      maglogo: N
    pubinfo:
      dt: May2018
      vid: 56
      iid: 5
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        129156222
        129156222
        NLM29094238
        10.1007/s11517-017-1739-2
        NLM29094238
        129156222
      ppf: 899
      ppct: 12
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Computational wear assessment of hard on hard hip implants subject to physically demanding tasks.
      aug:
        au:
          Nithyaprakash, R.
          Shankar, S.
          Uddin, M. S.
        affil: Department of Mechatronics Engineering, Kongu Engineering College, 638052, Erode, Tamil Nadu, India
      sug:
        subj:
          Joint Prosthesis
          Prosthesis Failure
          Computer Simulation
          Range of Motion
          Finite Element Analysis
          Pressure
          Stress, Mechanical
          Gait Physiology
      ab: Hip implants subject to gait loading due to occupational activities are potentially prone to failures such as osteolysis and aseptic loosening, causing painful revision surgeries. Highly risky gait activities such as carrying a load, stairs up or down and ladder up or down may cause excessive loading at the hip joint, resulting in generation of wear and related debris. Estimation of wear under the above gait activities is thus crucial to design and develop a new and improved implant component. With this motivation, this paper presents an assessment of wear generation of PCD-on-PCD (poly crystalline diamond) hip implants using finite element (FE) analysis. Three-dimensional (3D) FE model of hip implant along with peak gait and peak flexion angle for each activity was used to estimate wear of PCD for 10 million cycles. The maximum and minimum initial contact pressures of 206.19 MPa and 151.89 MPa were obtained for carrying load of 40 kg and sitting down or getting up activity. The simulation results obtained from finite element model also revealed that the maximum linear wear of 0.585 μm occurred for the patients frequently involved in sitting down or getting up gait activity and maximum volumetric wear of 0.025 mm3 for ladder up gait activity. The stair down activity showed the least linear and volumetric wear of 0.158 μm and 0.008 mm3, respectively, at the end of 10 million cycles. Graphical abstract Computational wear assessment of hip implants subjected to physically demanding tasks.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N