Airborne contaminants during controlled residential fires.

In this study, we characterize the area and personal air concentrations of combustion byproducts produced during controlled residential fires with furnishings common in 21st century single family structures. Area air measurements were collected from the structure during active fire and overhaul (pos...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Occupational & Environmental Hygiene Vol. 15; no. 5; pp. 399 - 413
Autores principales: Fent, Kenneth W., Evans, Douglas E., Babik, Kelsey, Striley, Cynthia, Bertke, Stephen, Kerber, Steve, Smith, Denise, Horn, Gavin P.
Formato: pictorial research tables/charts Journal Article
Publicado: Taylor & Francis Ltd May2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=129157088&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 129157088
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        15459624
        V1L
      jtl: Journal of Occupational & Environmental Hygiene
      issn: 15459624
      maglogo: Y
    pubinfo:
      dt: May2018
      vid: 15
      iid: 5
      pid: 377
      pub: Taylor & Francis Ltd
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        129157088
        129157088
        129157088
        10.1080/15459624.2018.1445260
        129157088
      ppf: 399
      ppct: 14
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Airborne contaminants during controlled residential fires.
      aug:
        au:
          Fent, Kenneth W.
          Evans, Douglas E.
          Babik, Kelsey
          Striley, Cynthia
          Bertke, Stephen
          Kerber, Steve
          Smith, Denise
          Horn, Gavin P.
        affil: Division of Surveillance, Hazard Evaluations, and Field Studies, National Institute for Occupational Safety and Health (NIOSH), Cincinnati, Ohio
      sug:
        subj:
          Environmental Monitoring
          Fires
          Home Environment
          Air
          Human
          Respiratory Protective Devices
          Ventilation
          Polycyclic Hydrocarbons, Aromatic
          Organic Chemicals
          Hydrocarbons, Aromatic
          Hydrogen Cyanide
          Occupational Exposure
          Blue Collar Workers
          Smoke
      ab: In this study, we characterize the area and personal air concentrations of combustion byproducts produced during controlled residential fires with furnishings common in 21st century single family structures. Area air measurements were collected from the structure during active fire and overhaul (post suppression) and on the fireground where personnel were operating without any respiratory protection. Personal air measurements were collected from firefighters assigned to fire attack, victim search, overhaul, outside ventilation, and command/pump operator positions. Two different fire attack tactics were conducted for the fires (6 interior and 6 transitional) and exposures were compared between the tactics. For each of the 12 fires, firefighters were paired up to conduct each job assignment, except for overhaul that was conducted by 4 firefighters. Sampled compounds included polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds (VOCs, e.g., benzene), hydrogen cyanide (HCN), and particulate (area air sampling only). Median personal air concentrations for the attack and search firefighters were generally well above applicable short-term occupational exposure limits, with the exception of HCN measured from search firefighters. Area air concentrations of all measured compounds decreased after suppression. Personal air concentrations of total PAHs and benzene measured from some overhaul firefighters exceeded exposure limits. Median personal air concentrations of HCN (16,300 ppb) exceeded the exposure limit for outside vent firefighters, with maximum levels (72,900 ppb) higher than the immediately dangerous to life and health (IDLH) level. Median air concentrations on the fireground (including particle count) were above background levels and highest when collected downwind of the structure and when ground-level smoke was the heaviest. No statistically significant differences in personal air concentrations were found between the 2 attack tactics. The results underscore the importance of wearing self-contained breathing apparatus when conducting overhaul or outside ventilation activities. Firefighters should also try to establish command upwind of the structure fire, and if this cannot be done, respiratory protection should be considered.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N