Comparison of Thermal Manikin Modeling and Human Subjects' Response During Use of Cooling Devices Under Personal Protective Ensembles in the Heat.

IntroductionPersonal protective equipment (PPE) recommended for use in West Africa during the Ebola outbreak increased risk for heat illness, and countermeasures addressing this issue would be valuable.Hypothesis/ProblemThe purpose of this study was to examine the physiological impact and heat perce...

Descripción completa

Detalles Bibliográficos
Publicado en:Prehospital & Disaster Medicine Vol. 33; no. 2; pp. 279 - 288
Autores principales: Quinn, Tyler, Kim, Jung-Hyun, Seo, Yongsuk, Coca, Aitor
Formato: research tables/charts Journal Article
Publicado: Cambridge University Press Jun2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=129908867&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 129908867
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        1049023X
        YX6
      jtl: Prehospital & Disaster Medicine
      issn: 1049023X
      maglogo: N
    pubinfo:
      dt: Jun2018
      vid: 33
      iid: 2
      pid: 15979
      pub: Cambridge University Press
    artinfo:
      ui:
        129908867
        129908867
        NLM29669616
        129908867
        10.1017/S1049023X18000328
        NLM29669616
        129908867
      ppf: 279
      ppct: 9
      formats:
      tig:
        atl: Comparison of Thermal Manikin Modeling and Human Subjects' Response During Use of Cooling Devices Under Personal Protective Ensembles in the Heat.
      aug:
        au:
          Quinn, Tyler
          Kim, Jung-Hyun
          Seo, Yongsuk
          Coca, Aitor
        affil: National Personal Protective Technology Laboratory, Pittsburgh, Pennsylvania USA
      sug:
        subj:
          Exercise Physiology
          Heat Prevention and Control
          Cold Equipment and Supplies
          Protective Devices
          Research Subjects Psychosocial Factors
          Models, Anatomic
          Human
          Male
          Africa, Western
          Environmental Exposure
          Ebola Virus
          Male
      ab: IntroductionPersonal protective equipment (PPE) recommended for use in West Africa during the Ebola outbreak increased risk for heat illness, and countermeasures addressing this issue would be valuable.Hypothesis/ProblemThe purpose of this study was to examine the physiological impact and heat perception of four different personal cooling devices (PCDs) under impermeable PPE during low-intensity exercise in a hot and humid environment using thermal manikin modeling and human testing.Methods: Six healthy male subjects walked on a treadmill in a hot/humid environment (32°C/92% relative humidity [RH]) at three metabolic equivalents (METs) for 60 minutes wearing PPE recommended for use in West Africa and one of four different personal cooling devices (PCDs; PCD1, PCD2, PCD3, and PCD4) or no PCD for control (CON). The same ensembles were tested with thermal manikin modeling software in the same conditions to compare the results.Results: All PCDs seemed to reduce physiological heat stress characteristics when worn under PPE compared to CON. Both the manikin and human testing provided similar results in core temperature (Tc) and heat sensation (HS) in both magnitude and relationship. While the manikin and human data provided similar skin temperature (Tsk) characterization, Tsk estimation by the manikin seemed to be slightly over-estimated. Weight loss, as estimated by the manikin, was under-estimated compared to the human measurement.Conclusion: Personal cooling device use in conjunction with impermeable PPE may be advantageous in mitigating physiological and perceptual burdens of heat stress. Evaluation of PCDs worn under PPE can be done effectively via human or manikin testing; however, Tsk may be over-estimated and weight loss may be under-estimated. Thermal manikin testing of PCDs may provide fast and accurate information to persons recommending or using PCDs with PPE. QuinnT, KimJH, SeoY, CocaA. Comparison of thermal manikin modeling and human subjects' response during use of cooling devices under personal protective ensembles in the heat. Prehosp Disaster Med. 2018;33(3):279-287.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N