Liver fibrosis detection and staging: a comparative study of T1ρ MR imaging and 2D real-time shear-wave elastography.

Purpose: To compare the results of T1ρ MR imaging and 2D real-time shear-wave elastography (SWE) for liver fibrosis detection and staging.Methods: Twenty-nine rabbit models of CCl4-induced liver fibrosis were established and six untreated rabbits served as controls. T1ρ MR imaging and 2D real-time S...

Descripción completa

Detalles Bibliográficos
Publicado en:Abdominal Radiology Vol. 43; no. 7; pp. 1713 - 1723
Autores principales: Yan, Fu-hua, Lin, Hui-min, Tao Wang, Zhao, Hong-fei, Li, Ruo-kun, Qiang, Jin-wei, Ren, Xin-pin, Chen, Wei-bo
Formato: Journal Article
Publicado: Springer Nature Jul2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=130627409&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 130627409
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        2366004X
        JT14
      jtl: Abdominal Radiology
      issn: 2366004X
      maglogo: N
    pubinfo:
      dt: Jul2018
      vid: 43
      iid: 7
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        130627409
        10.1007/s00261-017-1381-3
        130627409
      ppf: 1713
      ppct: 10
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Liver fibrosis detection and staging: a comparative study of T1ρ MR imaging and 2D real-time shear-wave elastography.
      aug:
        au:
          Yan, Fu-hua
          Lin, Hui-min
          Tao Wang
          Zhao, Hong-fei
          Li, Ruo-kun
          Qiang, Jin-wei
          Ren, Xin-pin
          Chen, Wei-bo
        affil: Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medcine, No. 197 Ruijin Er Road, Huangpu District, 200025, Shanghai, China
      sug:
      ab: Purpose: To compare the results of T1ρ MR imaging and 2D real-time shear-wave elastography (SWE) for liver fibrosis detection and staging.Methods: Twenty-nine rabbit models of CCl4-induced liver fibrosis were established and six untreated rabbits served as controls. T1ρ MR imaging and 2D real-time SWE examination were performed at 2, 4, 6, 8, 10, and 12 weeks. T1ρ values and liver stiffness (LS) values were measured. Fibrosis was staged according to the METAVIR scoring system. Correlation test was performed among T1ρ values, LS values, and fibrosis stage. Receiver operating characteristic (ROC) analysis was performed for assessing diagnostic performance of T1ρ and SWE in detection of no fibrosis (F0), substantial fibrosis (≥ F2), severe fibrosis (≥ F3), and cirrhosis (F4).Results: There was moderate positive correlation between fibrosis stage and T1ρ values (r = 0.566; 95% CI 0.291-0.754; P < 0.0001), and LS value (r = 0.726; 95% CI 0.521-0.851; P = 0.003). T1ρ values showed moderate positive correlations with LS values [r = 0.693; 95% confidence interval (CI) 0.472-0.832; P < 0.0001]. Areas Under ROC (AUROCs) were 0.861 (95% CI 0.705-0.953) for SWE and 0.856 (95% CI 0.698-0.950) for T1ρ (P = 0.940), 0.906 (95% CI 0.762-0.978) for SWE and 0.849 (95% CI 0.691-0.946) for T1ρ (P = 0.414), 0.870 (95% CI 0.716-0.958) for SWE and 0.799 (95% CI 0.632-0.913) for T1ρ (P = 0.422), and 0.846 (95% CI 0.687-0.944) for SWE and 0.692 (95% CI 0.517-0.835) for T1ρ (P = 0.137), when diagnosing liver fibrosis with ≥ F1, ≥ F2, ≥ F3, and F4, respectively. There was moderate positive correlation between inflammatory activity and T1ρ values (r = 0.520; 95% CI 0.158-0.807; P = 0.013).Conclusion: T1ρ imaging has potential for liver fibrosis detection and staging with good diagnostic capability similar to that of ultrasonography elastography.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N