Design and evaluation of an instrumented floor tile for measuring older adults' cardiac function at home.

Background Home monitoring of chronic diseases among older adults has been the focus of recent research as early detection of adverse events allows better management. Conventional medical devices require active engagement from the users, making it difficult to implement for people who have challenge...

Descripción completa

Detalles Bibliográficos
Publicado en:Gerontechnology Vol. 17; no. 2; pp. 77 - 90
Autores principales: Sung Jae Chang, Isaac, Javaid, Abdul Qadir, Boger, Jennifer, Arcelus, Amaya, Mihailidis, Alex
Formato: pictorial research tables/charts tracings Journal Article
Publicado: International Society for Gerontechnology 2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=131749025&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 131749025
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        15691101
        904R
      jtl: Gerontechnology
      issn: 15691101
      maglogo: N
    pubinfo:
      dt: 2018
      vid: 17
      iid: 2
      pid: 54298
      pub: International Society for Gerontechnology
    artinfo:
      ui:
        131749025
        131749025
        131749025
        10.4017/gt.2018.17.2.002.00
        131749025
      ppf: 77
      ppct: 13
      formats:
      tig:
        atl: Design and evaluation of an instrumented floor tile for measuring older adults' cardiac function at home.
      aug:
        au:
          Sung Jae Chang, Isaac
          Javaid, Abdul Qadir
          Boger, Jennifer
          Arcelus, Amaya
          Mihailidis, Alex
        affil: Institute of Biomaterials and Biomedical Engineering (IBBME), University of Toronto, Toronto, ON, M5S 3C9, Canada
      sug:
        subj:
          Heart Function Tests Equipment and Supplies
          Chronic Disease Diagnosis
          Monitoring, Physiologic Equipment and Supplies
          Floors and Floorcoverings
          Toilet Facilities
          Home Environment
          Electrocardiography
          Clinical Assessment Tools
          Instrument Construction
          Instrument Validation
          Human
          Posture
          Heart Rate
          Blood Pressure
          Aged
          Aged, 80 and Over
          Aged: 65+ years
          Aged, 80 & over
      ab: Background Home monitoring of chronic diseases among older adults has been the focus of recent research as early detection of adverse events allows better management. Conventional medical devices require active engagement from the users, making it difficult to implement for people who have challenges with using technology, such as people with cognitive impairment. While smart homes are a promising emerging approach to tackle this challenge, related technologies are still cumbersome to use. in response to this challenge, we present a zero-effort instrumented floor tile that could be permanently installed in a bathroom or kitchen to measure a person's ballistocardiogram (BCG) and electrocardiogram (ECG) signals as part of a smart home system. Methods The floor tile contained four load cells in a Wheatstone bridge configuration to measure BCG while standing and four electrodes to measure ECG while sitting. Both the BCG and ECG were amplified by 100dB and had rails of-9V to +9V. BCG and ECG from the tile were sampled at 128Hz. To validate the device, data were collected from 60 healthy adults in various sitting and standing scenarios. The ECG and BCG obtained from the tile compared to RR-intervals (time duration between two successive ECG R-peaks) and heartrate obtained from chest ECG collected with (gold standard) gelbased electrodes. The RJ-interval (time duration between the ECG R-peak and the highest peak in the BCG signal called the J-peak) was also examined for an induced change in blood pressure. Results The ECG signal measured from the tile in the sitting position had 89% agreement with the gold standard ECG. Heart rate based on BCG had an error of 1.8 ± 4.3% compared to that of the gold standard ECG. The RJ-interval was reduced postinduced blood pressure change and returned to the baseline after a few seconds, which is comparable to the literature. Conclusions The prototype tile presented in this work shows promising results as a zero-effort component in a smart home vitals monitoring system. With further modification and addition of intelligent algorithms, we believe the tile presented could collect ECG and BCG from older adults in a non-clinical setting.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        tracings
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N