Making smart pumps smarter, making IV therapy safer.

Errors of IV drug administration outweigh errors related to prescribing and have remained stubbornly fixed at an unacceptable level, with one study giving a rate of 74.5 errors per 100 patient days. A major challenge, therefore, in smart pump development has been 'closing the loop'—confirming correc...

Descripción completa

Detalles Bibliográficos
Publicado en:British Journal of Nursing Vol. 22; pp. 22 - 28
Autor principal: Waterson, James
Formato: tables/charts Journal Article
Publicado: Mark Allen Holdings Limited Jul2013 Supplement
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=132098242&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 132098242
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09660461
        GHD
      jtl: British Journal of Nursing
      issn: 09660461
      maglogo: N
    pubinfo:
      dt: Jul2013 Supplement
      vid: 22
      pid: 11383
      pub: Mark Allen Holdings Limited
    artinfo:
      ui:
        132098242
        132098242
        132098242
        10.12968/bjon.2013.22.Sup13.22
        132098242
      ppf: 22
      ppct: 6
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Making smart pumps smarter, making IV therapy safer.
      aug:
        au: Waterson, James
        affil: Clinical Consultant, CareFusion Limited
      sug:
        subj:
          Medication Errors Prevention and Control
          Infusion Pumps
          Administration, Intravenous
          Patient Safety
          Drug Information
          Libraries
          Drug Delivery Systems Methods
          Dosage Calculation
          Software Utilization
          Clinical Information Systems
          Multidisciplinary Care Team
          Health Care Delivery, Integrated
      ab: Errors of IV drug administration outweigh errors related to prescribing and have remained stubbornly fixed at an unacceptable level, with one study giving a rate of 74.5 errors per 100 patient days. A major challenge, therefore, in smart pump development has been 'closing the loop'—confirming correct administration and guiding clinicians at the point of administration. CareFusion smart pumps set 'rules' for every infusion through the application of a drug library. The effectiveness of this library can be monitored through a reporting system, which allows teams to make informed changes to therapies and limits. Creating the drug library is a multidisciplinary undertaking which often involves conflict and a rolling back of assumptions about current practices. Integrating smart pumps with electronic health records, and using auto-population to 'close the loop' for IV drug administration, release the potential of smart pumps to protect patients against drug administration error.
      pubtype: Academic Journal
      doctype:
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N