National survey on dose data analysis in computed tomography.

Objectives: A nationwide survey was performed assessing current practice of dose data analysis in computed tomography (CT).Material and Methods: All radiological departments in Switzerland were asked to participate in the on-line survey composed of 19 questions (16 multiple choice, 3 free text). It...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 28; no. 12; pp. 5044 - 5051
Autores principales: Heilmaier, Christina, Treier, Reto, Merkle, Elmar Max, Alkadhi, Hatem, Weishaupt, Dominik, Schindera, Sebastian
Formato: Journal Article
Publicado: Springer Nature Dec2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=132880989&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 132880989
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Dec2018
      vid: 28
      iid: 12
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        132880989
        132880989
        NLM29808427
        10.1007/s00330-018-5408-0
        NLM29808427
        132880989
      ppf: 5044
      ppct: 7
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: National survey on dose data analysis in computed tomography.
      aug:
        au:
          Heilmaier, Christina
          Treier, Reto
          Merkle, Elmar Max
          Alkadhi, Hatem
          Weishaupt, Dominik
          Schindera, Sebastian
        affil: Swiss Society of Radiology; c/o: ecos Office Center, Bellerivestrasse 11, CH-8008, Zürich, Switzerland
      sug:
        subj:
          Radiometry Standards
          Radiology Service Standards
          Tomography, X-Ray Computed Standards
          Quality Improvement
          Radiologic Health Standards
          Software
          Radiologic Health Methods
          Patient Safety
          Radiation Dosage
          Switzerland
          Radiometry Methods
          Tomography, X-Ray Computed Methods
          Questionnaires
          Scales
      ab: Objectives: A nationwide survey was performed assessing current practice of dose data analysis in computed tomography (CT).Material and Methods: All radiological departments in Switzerland were asked to participate in the on-line survey composed of 19 questions (16 multiple choice, 3 free text). It consisted of four sections: (1) general information on the department, (2) dose data analysis, (3) use of a dose management software (DMS) and (4) radiation protection activities.Results: In total, 152 out of 241 Swiss radiological departments filled in the whole questionnaire (return rate, 63%). Seventy-nine per cent of the departments (n = 120/152) analyse dose data on a regular basis with considerable heterogeneity in the frequency (1-2 times per year, 45%, n = 54/120; every month, 35%, n = 42/120) and method of analysis. Manual analysis is carried out by 58% (n = 70/120) compared with 42% (n = 50/120) of departments using a DMS. Purchase of a DMS is planned by 43% (n = 30/70) of the departments with manual analysis. Real-time analysis of dose data is performed by 42% (n = 21/50) of the departments with a DMS; however, residents can access the DMS in clinical routine only in 20% (n = 10/50) of the departments. An interdisciplinary dose team, which among other things communicates dose data internally (63%, n = 76/120) and externally, is already implemented in 57% (n = 68/120) departments.Conclusion: Swiss radiological departments are committed to radiation safety. However, there is high heterogeneity among them regarding the frequency and method of dose data analysis as well as the use of DMS and radiation protection activities.Key Points: • Swiss radiological departments are committed to and interest in radiation safety as proven by a 63% return rate of the survey. • Seventy-nine per cent of departments analyse dose data on a regular basis with differences in the frequency and method of analysis: 42% use a dose management software, while 58% currently perform manual dose data analysis. Of the latter, 43% plan to buy a dose management software. • Currently, only 25% of the departments add radiation exposure data to the final CT report.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N