Assessing auditory nerve condition by tone decay in deaf subjects with a cochlear implant.

The condition of the auditory nerve is a factor determining hearing performance of cochlear implant (CI) recipients. Abnormal loudness adaptation is associated with poor auditory nerve survival. We examined which stimulus conditions are suitable for tone decay measurements to differentiate between C...

Descripción completa

Detalles Bibliográficos
Publicado en:International Journal of Audiology Vol. 57; no. 11; pp. 864 - 872
Autores principales: Wasmann, Jan-Willem A., van Eijl, Ruben H. M., Versnel, Huib, van Zanten, Gijsbert A.
Formato: research tables/charts Journal Article
Publicado: Taylor & Francis Ltd Nov2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=132902440&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 132902440
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        14992027
        JW2
      jtl: International Journal of Audiology
      issn: 14992027
      maglogo: Y
    pubinfo:
      dt: Nov2018
      vid: 57
      iid: 11
      pid: 377
      pub: Taylor & Francis Ltd
      place: Philadelphia, Pennsylvania
    artinfo:
      ui:
        132902440
        132902440
        132902440
        10.1080/14992027.2018.1498598
        132902440
      ppf: 864
      ppct: 8
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Assessing auditory nerve condition by tone decay in deaf subjects with a cochlear implant.
      aug:
        au:
          Wasmann, Jan-Willem A.
          van Eijl, Ruben H. M.
          Versnel, Huib
          van Zanten, Gijsbert A.
        affil: Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
      sug:
        subj:
          Cochlear Implant
          Cochlear Nerve Physiopathology
          Deafness
          Speech Perception
          Human
          Male
          Female
          Adult
          Audiometry, Pure-Tone
          Hearing
          Data Analysis Software
          Wilcoxon Rank Sum Test
          Mann-Whitney U Test
          Pilot Studies
          Adult: 19-44 years
          Male
          Female
      ab: The condition of the auditory nerve is a factor determining hearing performance of cochlear implant (CI) recipients. Abnormal loudness adaptation is associated with poor auditory nerve survival. We examined which stimulus conditions are suitable for tone decay measurements to differentiate between CI recipients with respect to their speech perception. Tone decay was defined here as occurring when the percept disappears before the stimulus stops. We measured the duration of the percept of a 60-s pulse train. Current levels ranged from below threshold up to maximum acceptable loudness, pulse rates from 250 to 5000 pulses/s, and duty cycles (percentages of time the burst of pulses is on) from 10% to 100%. Ten adult CI recipients were included: seven with good and three with poor speech perception. Largest differences among the subjects were found at 5000 pulses/s and 100% duty cycle. The well performing subjects had a continuous percept of the 60-s stimulus within 3 dB above threshold. Two poorly performing subjects showed abnormal loudness adaptation, that is, no continuous percept even at levels greater than 6 dB above threshold. We conclude that abnormal loudness adaptation can be detected via an electric tone decay test using a high pulse rate and 100% duty cycle.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N