Measurement of Diaphragmatic Electrical Activity by Surface Electromyography in Intubated Subjects and Its Relationship With Inspiratory Effort.

BACKGROUND: Quantification of patient effort during spontaneous breathing is important to tailor ventilatory assistance. Because a correlation between inspiratory muscle pressure (Pmus) and electrical activity of the diaphragm (EAdi) has been described, we aimed to assess the reliability of surface...

Descripción completa

Detalles Bibliográficos
Publicado en:Respiratory Care Vol. 63; no. 11; pp. 1341 - 1350
Autores principales: Bellani, Giacomo, Bronco, Alfio, Arrigoni Marocco, Stefano, Pozzi, Matteo, Sala, Vittoria, Eronia, Nilde, Villa, Giulia, Foti, Giuseppe, Tagliabue, Giovanni, Eger, Marcus, Pesenti, Antonio
Formato: research tables/charts Journal Article
Publicado: Mary Ann Liebert, Inc. Nov2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=133121596&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 133121596
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00201324
        4GG
      jtl: Respiratory Care
      issn: 00201324
      maglogo: N
    pubinfo:
      dt: Nov2018
      vid: 63
      iid: 11
      pid: 1365
      pub: Mary Ann Liebert, Inc.
      place: New Rochelle, New York
    artinfo:
      ui:
        133121596
        133121596
        133121596
        10.4187/respcare.06176
        133121596
      ppf: 1341
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Measurement of Diaphragmatic Electrical Activity by Surface Electromyography in Intubated Subjects and Its Relationship With Inspiratory Effort.
      aug:
        au:
          Bellani, Giacomo
          Bronco, Alfio
          Arrigoni Marocco, Stefano
          Pozzi, Matteo
          Sala, Vittoria
          Eronia, Nilde
          Villa, Giulia
          Foti, Giuseppe
          Tagliabue, Giovanni
          Eger, Marcus
          Pesenti, Antonio
        affil: School of Medicine and Surgery, University of Milan-Bicocca, Monza, Italy
      sug:
        subj:
          Respiration, Artificial
          Diaphragm Physiology
          Inspiration, Respiratory
          Electromyography
          Reliability
          Human
          Italy
          Academic Medical Centers
          Intensive Care Units
          Pressure Support Ventilation
          Adult
          Middle Age
          Data Analysis Software
          Two-Way Analysis of Variance
          Linear Regression
          Descriptive Statistics
          Esophagus
          Pressure (Physiology)
          Adult: 19-44 years
          Middle Aged: 45-64 years
      ab: BACKGROUND: Quantification of patient effort during spontaneous breathing is important to tailor ventilatory assistance. Because a correlation between inspiratory muscle pressure (Pmus) and electrical activity of the diaphragm (EAdi) has been described, we aimed to assess the reliability of surface electromyography (EMG) of the respiratory muscles for monitoring diaphragm electrical activity and subject effort during assisted ventilation. METHODS: At a general ICU of a single university-affiliated hospital, we enrolled subjects who were intubated and on pressure support ventilation (PSV) and were on mechanical ventilation for > 48 h. The subjects were studied at 3 levels of pressure support. Airway flow and pressure; esophageal pressure; EAdi; and surface EMG of the diaphragm (surface EAdi), intercostal, and sternocleidomastoid muscles were recorded. Respiratory cycles were sampled for off-line analysis. The Pmus/EAdi index (PEI) was calculated by relying on EAdi and surface EAdi (surface PEI) from an airway pressure drop during end-expiratory occlusions performed every minute. RESULTS: surface EAdi well correlated with EAdi and Pmus, in particular, after averaging breaths into deciles (R = 0.92 and R = 0.84). When surface PEI was used with surface EAdi, it provided a reliable estimation of Pmus (R = 0.94 in comparison with measured Pmus). CONCLUSIONS: During assisted mechanical ventilation, EAdi can be reliably monitored by both EAdi and surface EMG. The measurement of Pmus based on the calibration of EAdi was also feasible by the use of surface EMG.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N