Effects of Fill Volume and Humidification on Aerosol Delivery During Single-Limb Noninvasive Ventilation.

BACKGROUND: The aim of this work was to determine the effect of fill volume and humidification change on aerosol delivery during single-limb noninvasive ventilation (NIV). METHODS: Four groups were recruited, each consisting of 12 subjects (6 females) with COPD receiving NIV. Groups 1 and 3 received...

Descripción completa

Detalles Bibliográficos
Publicado en:Respiratory Care Vol. 63; no. 11; pp. 1370 - 1379
Autores principales: Saeed, Haitham, Mohsen, Marwa, Eldin, Abeer Salah, Elberry, Ahmed A., Hussein, Raghda R. S., Rabea, Hoda, Abdelrahim, Mohamed E. A.
Formato: research tables/charts Journal Article
Publicado: Mary Ann Liebert, Inc. Nov2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=133121599&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 133121599
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        00201324
        4GG
      jtl: Respiratory Care
      issn: 00201324
      maglogo: N
    pubinfo:
      dt: Nov2018
      vid: 63
      iid: 11
      pid: 1365
      pub: Mary Ann Liebert, Inc.
      place: New Rochelle, New York
    artinfo:
      ui:
        133121599
        133121599
        133121599
        10.4187/respcare.06022
        133121599
      ppf: 1370
      ppct: 9
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Effects of Fill Volume and Humidification on Aerosol Delivery During Single-Limb Noninvasive Ventilation.
      aug:
        au:
          Saeed, Haitham
          Mohsen, Marwa
          Eldin, Abeer Salah
          Elberry, Ahmed A.
          Hussein, Raghda R. S.
          Rabea, Hoda
          Abdelrahim, Mohamed E. A.
        affil: Clinical Pharmacy Department, Faculty of Pharmacy, Beni-suef University, Beni-suef, Egypt
      sug:
        subj:
          Pulmonary Disease, Chronic Obstructive Drug Therapy
          Noninvasive Procedures
          Respiration, Artificial Methods
          Aerosols Administration and Dosage
          Drug Delivery Systems
          Administration, Inhalation
          Humidity
          Human
          Male
          Female
          Albuterol Administration and Dosage
          Nebulizers and Vaporizers
          In Vivo Studies
          Normal Saline
          Albuterol Urine
          Egypt
          Academic Medical Centers
          Data Analysis Software
          Post Hoc Analysis
          Descriptive Statistics
          Male
          Female
      ab: BACKGROUND: The aim of this work was to determine the effect of fill volume and humidification change on aerosol delivery during single-limb noninvasive ventilation (NIV). METHODS: Four groups were recruited, each consisting of 12 subjects (6 females) with COPD receiving NIV. Groups 1 and 3 received inhaled salbutamol with a vibrating mesh nebulizer, and Groups 2 and 4 received inhaled salbutamol with a jet nebulizer. The in vivo study was carried out on days 1 and 3. In groups 1 and 2, 2 fill-volumes were delivered to each subject; 1 mL 5,000 µg/mL salbutamol respirable solution used as it is or diluted to a total of 2 mL using normal saline. In groups 3 and 4, 1 mL 5,000 µg/mL salbutamol respirable solution diluted to 2 mL total volume using normal saline was delivered to each subject with and without humidification. Unchanged salbutamol in urine at 30 min (USAL0.5) and in pooled urine at 24 h (USAL24) was determined. On day 2, the ex vivo study was carried out on subjects using the same experimental setting with a filter placed proximal to their face mask for collection of total inhaled dose of salbutamol (aerosol emitted). RESULTS: The vibrating mesh nebulizer delivered higher USAL0.5, USAL24, and aerosol emitted compared to the jet nebulizer at all fill volumes and humidification conditions (P < .001). Increasing fill volume from 1 mL to 2 mL resulted in a significant increase in USAL0.5, USAL24, and aerosol emitted from the jet nebulizer (P < .05) with an insignificant effect on the vibrating mesh nebulizer. A 2-mL fill volume with the jet nebulizer delivered USAL24 and aerosol emitted comparable to those of 1 mL with the vibrating mesh nebulizer with significantly longer nebulization times (P < .001). Humidification had an insignificant effect on aerosol delivery. CONCLUSIONS: Increasing the fill volume of a jet nebulizer is essential to increase the amount of inhaled medication reaching a subject. In contrast, there is no need to increase fill volumes when using a vibrating mesh nebulizer. There is no need to switch off the humidifier while delivering aerosol through a singlelimb NIV circuit.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N