Aortic Remodeling After Total Endovascular Aortic Repair With Multilayer Stents: Computational Fluid Dynamics Analysis of Aortic Remodeling Over 3 Years of Follow-up.

Purpose: To report Multilayer Flow Modulator (MFM) implantation from the sinotubular junction to the distal infrarenal aorta in the treatment of type B aortic dissection (TBAD) and demonstrate aortic remodeling using computational fluid dynamics (CFD) analysis over the course of 3-year follow-up.Cas...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Endovascular Therapy Vol. 25; no. 6; pp. 760 - 765
Autores principales: Costache, Victor S., Yeung, Kak K., Solomon, Crina, Popa, Radu, Melnic, Tatiana, Sandu, Mihai, Bucurenciu, Cristian, Candea, Gabriela, Santa, Adrian, Costache, Andreea
Formato: case study Journal Article
Publicado: Sage Publications Inc. Dec2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=133562507&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 133562507
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        15266028
        IR3
      jtl: Journal of Endovascular Therapy
      issn: 15266028
      maglogo: Y
    pubinfo:
      dt: Dec2018
      vid: 25
      iid: 6
      pid: 344
      pub: Sage Publications Inc.
      place: Thousand Oaks, California
    artinfo:
      ui:
        133562507
        133562507
        NLM30354915
        133562507
        10.1177/1526602818808049
        NLM30354915
        133562507
      ppf: 760
      ppct: 5
      formats:
      tig:
        atl: Aortic Remodeling After Total Endovascular Aortic Repair With Multilayer Stents: Computational Fluid Dynamics Analysis of Aortic Remodeling Over 3 Years of Follow-up.
      aug:
        au:
          Costache, Victor S.
          Yeung, Kak K.
          Solomon, Crina
          Popa, Radu
          Melnic, Tatiana
          Sandu, Mihai
          Bucurenciu, Cristian
          Candea, Gabriela
          Santa, Adrian
          Costache, Andreea
        affil: NextCardio Project ULBS, Lucian Blaga University, Sibiu, Romania
      sug:
        subj:
          Aneurysm, Dissecting Surgery
          Models, Biological
          Blood Vessel Prosthesis
          Vascular Remodeling
          Computer Simulation
          Blood Vessel Prosthesis Equipment and Supplies
          Aortic Aneurysm Surgery
          Stents
          Aortic Aneurysm
          Prosthesis Design
          Male
          Physiochemical Phenomena
          Treatment Outcomes
          Middle Age
          Aneurysm, Dissecting Physiopathology
          Aortic Aneurysm Physiopathology
          Time Factors
          Aneurysm, Dissecting
          Questionnaires
          Middle Aged: 45-64 years
          Male
      ab: Purpose: To report Multilayer Flow Modulator (MFM) implantation from the sinotubular junction to the distal infrarenal aorta in the treatment of type B aortic dissection (TBAD) and demonstrate aortic remodeling using computational fluid dynamics (CFD) analysis over the course of 3-year follow-up.Case Report: A hypertensive patient with complicated TBAD required thoracic endovascular aortic repair due to severe thoracic pain associated with rapid progression of the false lumen aneurysm toward the distal aortic arch. Under general anesthesia, 2 aortic multilayer stents were placed over a 0.035-inch stiff guidewire in the compressed true lumen. The aorta was covered with 2 MFM stents between the sinotubular junction and the distal infrarenal aorta. Serial computed tomography scans showed progressive remodeling of the entire dissected aortic wall, with an excellent result at 24 months. Morphological and CFD vascular analysis confirmed the aortic remodeling, with a false lumen index drop from a preoperative 4.04 to 0.01 at 36 months.Conclusion: Endovascular aortic repair with multilayer stents is a promising treatment for complicated TBAD due to the unique ability of these devices to stabilize the entire aortic wall without compromising the flow in the major aortic side branches.
      pubtype: Academic Journal
      doctype:
        case study
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N