Algoritmo para estimación de ángulo de rodilla en marcha normal: enfoque a trazado de trayectoria en prótesis transfemorales inteligentes.

This paper presents an algorithm to estimate the knee angle from hip angle and gait parameters. This algorithm uses a single sensor on the thigh to achieve the estimation. Hip-knee natural correlations were employed in order to analyze the gait flexion-extension movements in two stages: 1) when the...

Descripción completa

Detalles Bibliográficos
Publicado en:Revista Mexicana de Ingeniería Biomédica Vol. 37; no. 3; pp. 221 - 234
Autores principales: Martínez-Solís, F., Ramírez-Betancour, R., Olmos-López, A., Rodríguez-Lelis, J. M., Claudio-Sánchez, A., González-Contreras, B.
Formato: Artículo
Publicado: Sociedad Mexicana de Ingenieria Biomedica, A.C. sep-dec2016
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=133626054&site=ehost-live
header:
  @attributes:
    shortDbName: lth
    uiTerm: 133626054
    longDbName: MedicLatina
    uiTag: AN
  controlInfo:
    bkinfo:
    jinfo:
      jid:
        01889532
        7L3
      jtl: Revista Mexicana de Ingeniería Biomédica
      issn: 01889532
      maglogo: N
    pubinfo:
      dt: sep-dec2016
      vid: 37
      iid: 3
      pid: 20850
      pub: Sociedad Mexicana de Ingenieria Biomedica, A.C.
    artinfo:
      ui:
        133626054
        10.17488/RMIB.37.3.7
      ppf: 221
      ppct: 13
      formats:
        fmt:
          @attributes:
            type: P
            size: 3.6MB
      tig:
        atl: Algoritmo para estimación de ángulo de rodilla en marcha normal: enfoque a trazado de trayectoria en prótesis transfemorales inteligentes.
      aug:
        au:
          Martínez-Solís, F.
          Ramírez-Betancour, R.
          Olmos-López, A.
          Rodríguez-Lelis, J. M.
          Claudio-Sánchez, A.
          González-Contreras, B.
        affil:
          División Académica de Ingeniería y Arquitectura, Universidad Juárez Autónoma de Tabasco. Cunduacán, Tabasco, México
          Tecnológico Nacional de México. Cuernavaca, Morelos, México
          Universidad Autónoma de Tlaxcala. Apizaco, Tlaxcala, México
      sug:
      keyword:
        estimate angle
        gait analysis
        intelligent prosthesis
        linear regression
        ángulo estimado
        análisis de marcha
        estimate angle
        gait analysis
        intelligent prosthesis
        linear regression
        prótesis inteligentes
        regresión lineal
      ab:
        This paper presents an algorithm to estimate the knee angle from hip angle and gait parameters. This algorithm uses a single sensor on the thigh to achieve the estimation. Hip-knee natural correlations were employed in order to analyze the gait flexion-extension movements in two stages: 1) when the foot is not in full contact with the floor (swing phase and heel contact); 2) when the whole sole makes contact with the ground (stance phase). The estimation is developed in real-time for gait movements and speed fluctuations do not distort the angle estimated. In addition, the simple linear regression were used to approximate the estimated angle to actual knee angle. The experimental results obtained from the gait studies, showed an acceptable knee angle approximation; the mean error estimation was 8.25. The major goal of this work was the development of an algorithm that can solve the problem of human body-intelligent transfemoral prosthesis coordination, even if there are gait speed fluctuations.
        En este trabajo se presenta un algoritmo para estimar el ángulo de rodilla a partir del ángulo de cadera y parámetros de marcha, el cual sólo utiliza un sensor en el muslo para la estimación. Para el desarrollo del algoritmo fue indispensable realizar un análisis de marcha para establecer parámetros de diseño. Se utilizó la correlación natural entre cadera y rodilla para separar los movimientos de flexión-extensión de marcha en dos etapas:1) movimientos donde el pie no está en contacto total con el piso; 2) movimientos de contacto total del pie con el piso. La estimación es para movimientos de marcha, se realiza en tiempo real y la variación de velocidad en la marcha no afecta la estimación del ángulo. Se utilizaron regresores lineales para aproximar el ángulo estimado de rodilla al ángulo real. En todos los casos de estudio de marcha, los resultados mostraron una aproximación aceptable del ángulo de la rodilla; el error promedio de estimación fue de 8.25. El principal logro de este trabajo fue desarrollar un algoritmo para dar una posible solución al problema de coordinación entre el cuerpo humano y prótesis transfemorales inteligentes, aun ante cambios de velocidad en la marcha.
      pubtype: Academic Journal
      doctype: Article
      src: R
    language: Spanish
    refInfo:
    copyright:
      @attributes:
        flag: Y
      custom: Copyright of Revista Mexicana de Ingeniería Biomédica is the property of Sociedad Mexicana de Ingenieria Biomedica, A.C. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use.
      item: Revista Mexicana de Ingeniería Biomédica
      holder: Sociedad Mexicana de Ingenieria Biomedica, A.C.
      dt:
        @attributes:
          year: 2016
    holdings:
      @attributes:
        islocal: N