Caracterización y Clasificación de Señales de Auscultación Cervical Adquiridas con Estetoscopio para Detección Automática de Sonidos Deglutorios.
Automatic evaluation of cervical auscultation sounds (AC) is a non-invasive tool for swallowing assessment. However, the swallowing events could be perturbed by acoustic noise. This paper proposes a methodology of characterization and classification of AC signals acquired by stethoscope with high te...
| Published in: | Revista Mexicana de Ingeniería Biomédica Vol. 39; no. 2; pp. 205 - 217 |
|---|---|
| Main Authors: | , , |
| Format: | Article |
| Published: |
Sociedad Mexicana de Ingenieria Biomedica, A.C.
may-aug2018
|
| Online Access: | View this record in EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=133631141&site=ehost-live header: @attributes: shortDbName: lth uiTerm: 133631141 longDbName: MedicLatina uiTag: AN controlInfo: bkinfo: jinfo: jid: 01889532 7L3 jtl: Revista Mexicana de Ingeniería Biomédica issn: 01889532 maglogo: N pubinfo: dt: may-aug2018 vid: 39 iid: 2 pid: 20850 pub: Sociedad Mexicana de Ingenieria Biomedica, A.C. artinfo: ui: 133631141 10.17488/RMIB.39.2.6 ppf: 205 ppct: 12 formats: fmt: @attributes: type: P size: 1.8MB tig: atl: Caracterización y Clasificación de Señales de Auscultación Cervical Adquiridas con Estetoscopio para Detección Automática de Sonidos Deglutorios. aug: au: Sánchez-Cardona, Y. Orozco-Duque, A. Roldán-Vasco, S. affil: Instituto Tecnológico Metropolitano, Medellín, Colombia Universidad de Antioquia, Medellín, Colombia sug: keyword: cepstral analysis cervical auscultation classification algorithm stethoscope swallowing swallowing sounds algoritmo de clasificación análisis cepstral auscultación cervical cepstral analysis cervical auscultation classification algorithm deglución estetoscopio sonidos deglutorios stethoscope swallowing swallowing sounds ab: Automatic evaluation of cervical auscultation sounds (AC) is a non-invasive tool for swallowing assessment. However, the swallowing events could be perturbed by acoustic noise. This paper proposes a methodology of characterization and classification of AC signals acquired by stethoscope with high temporal resolution, in order to discriminate between swallowing sounds and other acoustic noise. AC signals from 10 healthy individuals were acquired with stethoscope during three tasks: liquid ingestion, phoneme /a/ pronunciation and throat clearing. Features based in Mel frequency cepstral coefficients, discrete wavelet transform and Shannon entropy, were extracted. Features with highest Fisher's discriminant ratio were used as input of a support vector machine. By application of 60 ms windows and cross validation, the obtained accuracies were 97.7% for acoustic event detection and 91.7% for swallowing sound detection. The proposed method allows classification swallowing sounds with higher temporal resolution than other works but with comparable accuracy. Furthermore, the use of stethoscope could lead to better acceptation than other sensors by physicians, because it is a common device in clinical practice. This work is a first stage in the development of a robust classification algorithm for sounds in swallowing disorders, oriented to automatic diagnosis. La evaluación automática de sonidos de auscultación cervical (AC) es una herramienta no invasiva para evaluación de la deglución. Sin embargo, los eventos deglutorios pueden verse enmascarados por fuentes de ruido. Este trabajo propone una metodología de caracterización y clasificación de señales de AC con alta resolución temporal a partir de estetoscopio, para discriminar entre sonidos deglutorios y asociados a ruido. Se adquirieron señales de AC en 10 sujetos sanos durante tres pruebas: toma de líquido, pronunciación del fonema /a/ y aclaramiento de garganta. Se extrajeron características de la señal de AC basadas en coeficientes cepstrales en la escala Mel, transformada wavelet discreta y entropía de Shannon. Las características con mayor relevancia fueron utilizadas como entrada a una máquina de vectores de soporte. Utilizando ventanas de 60 ms - alta resolución temporal - y validación cruzada, se obtuvieron exactitudes del 97.7% para detección de eventos acústicos y 91.7% para sonidos deglutorios. El método propuesto permite clasificación de sonidos deglutorios utilizando estetoscopio -dispositivo común en la práctica clínica- con exactitud comparable a otros trabajos que tienen menor resolución temporal o que utilizan otro tipo de sensores. Este trabajo constituye una primera etapa en el desarrollo de un algoritmo robusto para clasificación de sonidos deglutorios asociados a desórdenes de la deglución, a partir de auscultación cervical, para fines de diagnóstico automático. pubtype: Academic Journal doctype: Article src: R language: Spanish refInfo: copyright: @attributes: flag: Y custom: Copyright of Revista Mexicana de Ingeniería Biomédica is the property of Sociedad Mexicana de Ingenieria Biomedica, A.C. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. item: Revista Mexicana de Ingeniería Biomédica holder: Sociedad Mexicana de Ingenieria Biomedica, A.C. dt: @attributes: year: 2018 holdings: @attributes: islocal: N |
|---|