Simulation of dosimetry impact of 4DCT uncertainty in 4D dose calculation for lung SBRT.

Background: Due to the heterogeneity of patient's individual respiratory motion pattern in lung stereotactic body radiotherapy (SBRT), treatment planning dose assessment using a traditional four-dimensional computed tomography (4DCT_traditional) images based on a uniform breathing curve may not repr...

Descripción completa

Detalles Bibliográficos
Publicado en:Radiation Oncology Vol. 14; no. 1
Autores principales: Liu, Gang, Hu, Fala, Ding, Xuanfeng, Li, Xiaoqiang, Shao, Qihong, Wang, Yuenan, Yang, Jing, Quan, Hong
Formato: Journal Article
Publicado: BioMed Central 1/8/2019
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=134014449&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 134014449
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        1748717X
        38NX
      jtl: Radiation Oncology
      issn: 1748717X
      maglogo: N
    pubinfo:
      dt: 1/8/2019
      vid: 14
      iid: 1
      pid: 24147
      pub: BioMed Central
    artinfo:
      ui:
        134014449
        134014449
        NLM30621744
        10.1186/s13014-018-1191-y
        NLM30621744
        134014449
      ppct: 1
      formats:
      tig:
        atl: Simulation of dosimetry impact of 4DCT uncertainty in 4D dose calculation for lung SBRT.
      aug:
        au:
          Liu, Gang
          Hu, Fala
          Ding, Xuanfeng
          Li, Xiaoqiang
          Shao, Qihong
          Wang, Yuenan
          Yang, Jing
          Quan, Hong
        affil: Key Laboratory of Artificial Micro- and Nano- structures of Ministry of Education and Center for Electronic Microscopy, School of Physics and Technology, Wuhan University, 430072, Wuhan, China
      sug:
        subj:
          Radiotherapy, Computer-Assisted Methods
          Diagnostic Imaging Methods
          Radiosurgery Methods
          Radiotherapy, Conformal Methods
          Lung Neoplasms Surgery
          Phantoms, Imaging
          Tomography, X-Ray Computed Methods
          Computer Simulation
          Image Interpretation, Computer Assisted
          Radiation Dosage
          Movement
          Respiration
          Impact of Events Scale
      ab: Background: Due to the heterogeneity of patient's individual respiratory motion pattern in lung stereotactic body radiotherapy (SBRT), treatment planning dose assessment using a traditional four-dimensional computed tomography (4DCT_traditional) images based on a uniform breathing curve may not represent the true treatment dose delivered to the patient. The purpose of this study was to evaluate the accumulated dose discrepancy between based on the 4DCT_traditional and true 4DCT (4DCT_true) that incorporated with the patient's real entire breathing motion. The study also explored a novel 4D robust planning strategy to compensate for such heterogeneity respiratory motion uncertainties.Methods: Simulated and measured patient specific breathing curves were used to generate 4D targets motion CT images. Volumetric-modulated arc therapy (VMAT) was planned using two arcs. Accumulated dose was obtained by recalculating the plan dose on each individual phase image and then deformed the dose from each phase image to the reference image. The "4 D dose" (D4D) and "true dose" (Dtrue) were the accumulated dose based on the 4DCT_traditional and 4DCT_true respectively. The average worse case dose discrepancy ([Formula: see text]) between D4D and Dtrue in all treatment fraction was calculated to evaluate dosimetric /planning parameters and correlate them with the heterogeneity of respiratory-induced motion patterns. A novel 4D robust optimization strategy for VMAT (4D Ro-VMAT) based on the probability density function(pdf) of breathing curve was proposed to improve the target coverage in the presence of heterogeneity respiratory motion. The data were assessed with a paired t-tests.Results: With increasing breathing amplitude from 5 to 20 mm, target [Formula: see text], [Formula: see text] increased from 1.59,1.39 to 10.15%,8.66% respectively. When the standard deviation of breathing amplitude increased from 15 to 35% of the mean amplitude, [Formula: see text], [Formula: see text] increased from 4.06,3.48 to 10.25%,6.63% respectively. The 4D Ro-VMAT plan significantly improve the target dose compared to VMAT plan.Conclusion: When the breathing curve amplitude is more than 10 mm and standard deviation of amplitude is higher than 25% of mean amplitude, special care is needed to choose an appropriated dose accumulation approach to evaluate lung SBRT plan target coverage robustness. The proposed 4D Ro_VMAT strategy based on the pdf of patient specific breathing curve could effectively compensate such uncertainties.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N