Upgrade to Nucleus® 6 in Previous Generation Cochlear™ Sound Processor Recipients.

Background: The Nucleus ® 6 sound processor is now compatible with the Nucleus ® 22 (CI22M)--Cochlear's first generation cochlear implant. The Nucleus 6 offers three new signal processing algorithms that purportedly facilitate improved hearing in background noise. Purpose: These studies were designe...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of the American Academy of Audiology Vol. 29; no. 9; pp. 802 - 814
Autores principales: Biever, Allison, Gilden, Jan, Zwolan, Teresa, Mears, Megan, Beiter, Anne
Formato: pictorial research tables/charts Journal Article
Publicado: Thieme Medical Publishing Inc. Oct2018
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=134054070&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 134054070
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10500545
        9OC
      jtl: Journal of the American Academy of Audiology
      issn: 10500545
      maglogo: Y
    pubinfo:
      dt: Oct2018
      vid: 29
      iid: 9
      pid: 2811
      pub: Thieme Medical Publishing Inc.
      place: New York, New York
    artinfo:
      ui:
        134054070
        134054070
        134054070
        10.3766/jaaa.17016
        134054070
      ppf: 802
      ppct: 12
      formats:
        fmt:
          @attributes:
            type: P
      tig:
        atl: Upgrade to Nucleus® 6 in Previous Generation Cochlear™ Sound Processor Recipients.
      aug:
        au:
          Biever, Allison
          Gilden, Jan
          Zwolan, Teresa
          Mears, Megan
          Beiter, Anne
        affil: Rocky Mountain Ear Center, Englewood, CO
      sug:
        subj:
          Cochlear Implant Equipment and Supplies
          Speech Perception Evaluation
          Consumer Satisfaction Evaluation
          Human
          Prospective Studies
          North America
          Questionnaires
          Adolescence
          Adult
          Middle Age
          Aged
          Aged, 80 and Over
          Scales
          T-Tests
          Wilcoxon Signed Rank Test
          Adolescent: 13-18 years
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Aged: 65+ years
          Aged, 80 & over
      ab: Background: The Nucleus ® 6 sound processor is now compatible with the Nucleus ® 22 (CI22M)--Cochlear's first generation cochlear implant. The Nucleus 6 offers three new signal processing algorithms that purportedly facilitate improved hearing in background noise. Purpose: These studies were designed to evaluate listening performance and user satisfaction with the Nucleus 6 sound processor. Research Design: The research design was a prospective, single-participant, repeated measures design Study Sample: A group of 80 participants implanted with various Nucleus internal implant devices (CI22M, CI24M, Freedom ® CI24RE, CI422, and CI512) were recruited from a total of six North American sites. Data Collection and Analysis: Participants had their external sound processor upgraded to the Nucleus 6 sound processor. Final speech perception testing in noise and subjective questionnaires were completed after four or 12 weeks of take-home use with the Nucleus 6. Results: Speech perception testing in noise showed significant improvement and participants reported increased satisfaction with the Nucleus 6. Conclusion: These studies demonstrated the benefit of the new algorithms in the Nucleus 6 over previous generations of sound processors.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N