Setting Standards for Reporting and Quantification in Fluorescence-Guided Surgery.

Purpose: Intraoperative fluorescence imaging (FI) is a promising technique that could potentially guide oncologic surgeons toward more radical resections and thus improve clinical outcome. Despite the increase in the number of clinical trials, fluorescent agents and imaging systems for intraoperativ...

Descripción completa

Detalles Bibliográficos
Publicado en:Molecular Imaging & Biology Vol. 21; no. 1; pp. 11 - 19
Autores principales: Hoogstins, Charlotte, Burggraaf, Jan Jaap, Koller, Marjory, Handgraaf, Henricus, Boogerd, Leonora, van Dam, Gooitzen, Vahrmeijer, Alexander, Burggraaf, Jacobus
Formato: equations & formulas pictorial research tables/charts Journal Article
Publicado: Springer Nature Feb2019
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=134786714&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 134786714
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        15361632
        KJU
      jtl: Molecular Imaging & Biology
      issn: 15361632
      maglogo: N
    pubinfo:
      dt: Feb2019
      vid: 21
      iid: 1
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        134786714
        134786714
        NLM29845427
        134786714
        10.1007/s11307-018-1220-0
        NLM29845427
        134786714
      ppf: 11
      ppct: 8
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Setting Standards for Reporting and Quantification in Fluorescence-Guided Surgery.
      aug:
        au:
          Hoogstins, Charlotte
          Burggraaf, Jan Jaap
          Koller, Marjory
          Handgraaf, Henricus
          Boogerd, Leonora
          van Dam, Gooitzen
          Vahrmeijer, Alexander
          Burggraaf, Jacobus
        affil: Department of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333, Leiden, ZA, the Netherlands
      sug:
        subj:
          Image Processing, Computer Assisted Equipment and Supplies
          Practice Guidelines
          Diagnostic Imaging Standards
          Intraoperative Monitoring Equipment and Supplies
          Intraoperative Monitoring Standards
          Intraoperative Monitoring Methods
          Diagnostic Imaging Methods
          Surgery, Computer-Assisted Methods
          Surgery, Computer-Assisted Standards
          Image Processing, Computer Assisted Standards
          Image Processing, Computer Assisted Methods
          Calibration
          Neoplasms Pathology
          Neoplasms Surgery
          Reproducibility of Results
          Neoplasms Diagnosis
          Study Design Standards
          Risk Assessment Standards
          Sensitivity and Specificity
          Surgery, Computer-Assisted Equipment and Supplies
          Human
          Weights and Measures
          Animal Studies
          Diagnostic Imaging Equipment and Supplies
          Validation Studies
          Comparative Studies
          Evaluation Research
          Multicenter Studies
      ab: Purpose: Intraoperative fluorescence imaging (FI) is a promising technique that could potentially guide oncologic surgeons toward more radical resections and thus improve clinical outcome. Despite the increase in the number of clinical trials, fluorescent agents and imaging systems for intraoperative FI, a standardized approach for imaging system performance assessment and post-acquisition image analysis is currently unavailable.Procedures: We conducted a systematic, controlled comparison between two commercially available imaging systems using a novel calibration device for FI systems and various fluorescent agents. In addition, we analyzed fluorescence images from previous studies to evaluate signal-to-background ratio (SBR) and determinants of SBR.Results: Using the calibration device, imaging system performance could be quantified and compared, exposing relevant differences in sensitivity. Image analysis demonstrated a profound influence of background noise and the selection of the background on SBR.Conclusions: In this article, we suggest clear approaches for the quantification of imaging system performance assessment and post-acquisition image analysis, attempting to set new standards in the field of FI.
      pubtype: Academic Journal
      doctype:
        equations & formulas
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N