Magnetic resonance elastography SE-EPI vs GRE sequences at 3T in a pediatric population with liver disease.
Purpose: The goal of our study is to compare hepatic stiffness measures using gradient-recalled echo (GRE) versus spin-echo echo planar imaging (SE-EPI)-based MR Elastography (MRE) at 3T used to measure hepatic stiffness in a patients with suspected liver diseases.Materials and methods: This retrosp...
| Publicado en: | Abdominal Radiology Vol. 44; no. 3; pp. 894 - 903 |
|---|---|
| Autores principales: | , , , , , , |
| Formato: | Journal Article |
| Publicado: |
Springer Nature
Mar2019
|
| Acceso en línea: | Ver este registro en EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=135395021&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 135395021 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 2366004X JT14 jtl: Abdominal Radiology issn: 2366004X maglogo: N pubinfo: dt: Mar2019 vid: 44 iid: 3 pid: 237 pub: Springer Nature place: New York, New York artinfo: ui: 135395021 10.1007/s00261-018-1884-6 135395021 ppf: 894 ppct: 9 formats: fmt: – @attributes: type: T – @attributes: type: P tig: atl: Magnetic resonance elastography SE-EPI vs GRE sequences at 3T in a pediatric population with liver disease. aug: au: Calle-Toro, Juan S. Serai, Suraj D. Hartung, Erum A. Goldberg, David J. Bolster, Bradley D. Darge, Kassa Anupindi, Sudha A. affil: Division of Body Imaging, Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd, Philadelphia, PA, USA sug: ab: Purpose: The goal of our study is to compare hepatic stiffness measures using gradient-recalled echo (GRE) versus spin-echo echo planar imaging (SE-EPI)-based MR Elastography (MRE) at 3T used to measure hepatic stiffness in a patients with suspected liver diseases.Materials and methods: This retrospective study included 52 patients with liver disease who underwent a 3T MRE exam including both an investigational SE-EPI-based technique and a product GRE-based technique. Regions of interest (ROI) were placed on the elastograms to measure elastography-derived liver stiffness as well as the area included within the ROIs. The mean liver stiffness values and area of ROIs were compared.Results: The mean liver stiffness was 3.72 kilopascal (kPa) ± 1.29 using GRE MRE and 3.78 kPa ± 1.13 using SE-EPI MRE. Measurement of liver stiffness showed excellent agreement between the two pulse sequences with a mean bias of − 0.1 kPa (range − 1.8 to 1.7 kPa) between sequences. The mean measurable ROI area was higher with SE-EPI (313.8 cm2 ± 213.8) than with the GRE technique (208.6 cm2 ± 114.8), and the difference was statistically significant (P < 0.05).Conclusions: Our data shows excellent agreement of measured liver stiffness between GRE and SE-EPI-based sequences at 3T. Our results show the advantage of a SE-EPI MRE sequence in terms of image quality, ROI size and acquisition time with equivalent liver stiffness measurements as compared to GRE-MRE sequence. pubtype: Academic Journal doctype: Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|