Image quality and diagnostic accuracy of complex-averaged high b value images in diffusion-weighted MRI of prostate cancer.

Purpose: To evaluate the impact of complex-averaging on image quality (IQ) and diagnostic accuracy of acquired and calculated high b value (aHBV, cHBV) images in diffusion-weighted prostate MRI. Materials and methods: This retrospective study included 84 patients who underwent multiparametric prosta...

Descripción completa

Detalles Bibliográficos
Publicado en:Abdominal Radiology Vol. 44; no. 6; pp. 2244 - 2254
Autores principales: Kordbacheh, Hamed, Cecconi, Martina, Baliyan, Vinit, Chulroek, Thitinan, Seethamraju, Ravi Teja, Weiland, Elisabeth, Kiefer, Berthold, Nickel, Marcel Dominik, Harisinghani, Mukesh G.
Formato: Journal Article
Publicado: Springer Nature Jun2019
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=136674618&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 136674618
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        2366004X
        JT14
      jtl: Abdominal Radiology
      issn: 2366004X
      maglogo: N
    pubinfo:
      dt: Jun2019
      vid: 44
      iid: 6
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        136674618
        10.1007/s00261-019-01961-0
        136674618
      ppf: 2244
      ppct: 10
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Image quality and diagnostic accuracy of complex-averaged high b value images in diffusion-weighted MRI of prostate cancer.
      aug:
        au:
          Kordbacheh, Hamed
          Cecconi, Martina
          Baliyan, Vinit
          Chulroek, Thitinan
          Seethamraju, Ravi Teja
          Weiland, Elisabeth
          Kiefer, Berthold
          Nickel, Marcel Dominik
          Harisinghani, Mukesh G.
        affil: Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, White 270, 02114, Boston, MA, USA
      sug:
      ab: Purpose: To evaluate the impact of complex-averaging on image quality (IQ) and diagnostic accuracy of acquired and calculated high b value (aHBV, cHBV) images in diffusion-weighted prostate MRI. Materials and methods: This retrospective study included 84 patients who underwent multiparametric prostate MRI at 3 Tesla without endorectal coil. DWIs were acquired at three different b values which included two lower b values (b = 50,900 s/mm2) and one higher b value (aHBV at 2000 s/mm2). The acquired data were postprocessed to generate two different types of trace-weighted images—using conventional magnitude-averaging and complex-averaging. Using lower b values (b = 50,900 s/mm2) from both conventional and complex-averaged image sets, cHBV images (b = 2000 s/mm2) and ADC maps were derived. All image sets were reviewed by two radiologists in different reading sessions to assess image quality and PIRADS. The diagnostic accuracy of different image sets for the detection of prostate lesions was performed by correlating PIRADS and Gleason scores. Results: Complex-averaging did not impact ADC values of the prostate lesions compared to magnitude-averaging (P = 0.08). Complex-averaging improved image quality of acquired high b value and calculated high b value images (P < 0.0001). Complex-averaging also improved the level of confidence (LOC) of the acquired high b value for both readers (P < 0.0001, P < 0.05), but only for reader A in calculated high b value (P < 0.0001). The image quality of calculated high b value images was not significantly different than acquired high b value images. The dataset combining complex-averaging and calculated high b value provided the highest diagnostic accuracy (but not statistically significant) for detection of the significant prostate lesion compared to the magnitude-averaged acquired high b value (79.55% vs. 72.73%; P = 0.317). The mean acquisition time for b = 2000 s/mm2 sequence (aHBV) was 6 min 30 s (± 1 min 16 s) out of a total of 28 min 31 s (± 4 min 26 s) for the entire mp-MRI protocol (approximately 25% of total scan time). Conclusion: Complex-averaging provides better image quality and level of confidence without significant impact on ADC values and diagnostic accuracy for detection of the significant prostate lesions. The calculated high b value images are also comparable to (and can substitute) the acquired high b value images which can help in reducing the imaging time.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N