Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study.

Background: Until now, a few studies have addressed the accuracy of intraoral scanners (IOSs) in implantology. Hence, the aim of this in vitro study was to assess the accuracy of 5 different IOSs in the impressions of single and multiple implants, and to compare them. Methods: Plaster models were pr...

Descripción completa

Detalles Bibliográficos
Publicado en:BMC Oral Health Vol. 19; no. 1
Autores principales: Mangano, Francesco Guido, Hauschild, Uli, Veronesi, Giovanni, Imburgia, Mario, Mangano, Carlo, Admakin, Oleg
Formato: pictorial research tables/charts Journal Article
Publicado: BioMed Central 6/6/2019
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=136839642&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 136839642
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        14726831
        1CIC
      jtl: BMC Oral Health
      issn: 14726831
      maglogo: N
    pubinfo:
      dt: 6/6/2019
      vid: 19
      iid: 1
      pid: 24147
      pub: BioMed Central
    artinfo:
      ui:
        136839642
        136839642
        136839642
        10.1186/s12903-019-0792-7
        136839642
      ppct: 1
      formats:
      tig:
        atl: Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study.
      aug:
        au:
          Mangano, Francesco Guido
          Hauschild, Uli
          Veronesi, Giovanni
          Imburgia, Mario
          Mangano, Carlo
          Admakin, Oleg
        affil: Department of Prevention and Communal Dentistry, Sechenov First Moscow State Medical University, Moscow, Russia
      sug:
        subj:
          Digital Imaging Methods
          Digital Imaging Equipment and Supplies
          Validity
          Scanners
          Dental Impression
          Dental Implants
          In Vitro Studies
          Dental Prosthesis
          Jaw, Edentulous
          Software
          Precision
          Descriptive Statistics
          Laboratories, Dental
          Computer-Aided Design
      ab: Background: Until now, a few studies have addressed the accuracy of intraoral scanners (IOSs) in implantology. Hence, the aim of this in vitro study was to assess the accuracy of 5 different IOSs in the impressions of single and multiple implants, and to compare them. Methods: Plaster models were prepared, representative of a partially edentulous maxilla (PEM) to be restored with a single crown (SC) and a partial prosthesis (PP), and a totally edentulous maxilla (TEM) to be restored with a full-arch (FA). These models were scanned with a desktop scanner, to capture reference models (RMs), and with 5 IOSs (CS 3600®, Trios3®, Omnicam®, DWIO®, Emerald®); 10 scans were taken for each model, using each IOS. All IOS datasets were loaded into a reverse-engineering software where they were superimposed on the corresponding RMs, to evaluate trueness, and superimposed on each other within groups, to determine precision. A statistical analysis was performed. Results: In the SC, CS 3600® had the best trueness (15.2 ± 0.8 μm), followed by Trios3® (22.3 ± 0.5 μm), DWIO® (27.8 ± 3.2 μm), Omnicam® (28.4 ± 4.5 μm), Emerald® (43.1 ± 11.5 μm). In the PP, CS 3600® had the best trueness (23 ± 1.1 μm), followed by Trios3® (28.5 ± 0.5 μm), Omnicam® (38.1 ± 8.8 μm), Emerald® (49.3 ± 5.5 μm), DWIO® (49.8 ± 5 μm). In the FA, CS 3600® had the best trueness (44.9 ± 8.9 μm), followed by Trios3® (46.3 ± 4.9 μm), Emerald® (66.3 ± 5.6 μm), Omnicam® (70.4 ± 11.9 μm), DWIO® (92.1 ± 24.1 μm). Significant differences were found between the IOSs; a significant difference in trueness was found between the contexts (SC vs. PP vs. FA). In the SC, CS 3600® had the best precision (11.3 ± 1.1 μm), followed by Trios3® (15.2 ± 0.8 μm), DWIO® (27.1 ± 10.7 μm), Omnicam® (30.6 ± 3.3 μm), Emerald® (32.8 ± 10.7 μm). In the PP, CS 3600® had the best precision (17 ± 2.3 μm), followed by Trios3® (21 ± 1.9 μm), Emerald® (29.9 ± 8.9 μm), DWIO® (34.8 ± 10.8 μm), Omnicam® (43.2 ± 9.4 μm). In the FA, Trios3® had the best precision (35.6 ± 3.4 μm), followed by CS 3600® (35.7 ± 4.3 μm), Emerald® (61.5 ± 18.1 μm), Omnicam® (89.3 ± 14 μm), DWIO® (111 ± 24.8 μm). Significant differences were found between the IOSs; a significant difference in precision was found between the contexts (SC vs. PP vs. FA). Conclusions: The IOSs showed significant differences between them, both in trueness and in precision. The mathematical error increased in the transition from SC to PP up to FA, both in trueness than in precision.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N