Performance evaluation of a self‐administered home oral glucose tolerance test kit in a controlled clinical research setting.

Aim: To evaluate the performance of the current, pre‐production version of a novel home oral glucose tolerance test (Home OGTT) device when administered by trained research nurses, compared with a reference laboratory glucose analyser and a second laboratory analyser, incorporating a sample processi...

Descripción completa

Detalles Bibliográficos
Publicado en:Diabetic Medicine Vol. 36; no. 7; pp. 862 - 868
Autores principales: Dunseath, G. J., Bright, D., Jones, C., Dowrick, S., Cheung, W.‐Y., Luzio, S. D.
Formato: pictorial research tables/charts Journal Article
Publicado: Wiley-Blackwell Jul2019
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=136998611&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 136998611
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        07423071
        F07
      jtl: Diabetic Medicine
      issn: 07423071
      maglogo: Y
    pubinfo:
      dt: Jul2019
      vid: 36
      iid: 7
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        136998611
        136998611
        136998611
        10.1111/dme.13961
        136998611
      ppf: 862
      ppct: 6
      formats:
      tig:
        atl: Performance evaluation of a self‐administered home oral glucose tolerance test kit in a controlled clinical research setting.
      aug:
        au:
          Dunseath, G. J.
          Bright, D.
          Jones, C.
          Dowrick, S.
          Cheung, W.‐Y.
          Luzio, S. D.
        affil: Swansea University – Diabetes Research Group, Swansea UK
      sug:
        subj:
          Glucose Tolerance Test Methods
          Home Diagnostic Tests Methods
          Self-Diagnosis Methods
          Blood Glucose Monitoring Methods
          Nurse Attitudes
          Clinical Research
          Sensitivity and Specificity
          Human
          Female
          Young Adult
          Adult
          Middle Age
          Glucose Intolerance
          Fasting
          Blood Glucose
          Adult: 19-44 years
          Middle Aged: 45-64 years
          Female
      ab: Aim: To evaluate the performance of the current, pre‐production version of a novel home oral glucose tolerance test (Home OGTT) device when administered by trained research nurses, compared with a reference laboratory glucose analyser and a second laboratory analyser, incorporating a sample processing delay to simulate normal practice. Methods: One hundred women (aged 19–48 years), with and without known glucose intolerance were recruited. Following an overnight fast, participants attended for a 75‐g OGTT. A fasting capillary sample was applied to the Home OGTT device with a corresponding venous sample collected and measured immediately on the reference YSI 2300 stat plus analyser, and following a 1‐h delay on the Randox Daytona Plus analyser. The sampling process was repeated 2 h after the oral glucose load. Results: Some 97% of tested devices gave complete data for analysis. Good agreement was observed between the reference glucose analyser and the Home OGTT device, with the Home OGTT device displaying a small negative bias (−0.18 mmol/l, −1.75 to 1.39 mmol/mol; −1.0%, −26.4% to 24.5%; absolute and relative mean, 95% limits of agreement). When classified as normal glucose tolerant or glucose intolerant, the Home OGTT device showed 100% and 90% sensitivity, and 99% and 99% specificity using fasting plasma glucose and 2‐h glucose respectively. Similar sensitivity (100% and 100%) and specificity (96% and 99%) for fasting plasma glucose and 2‐h glucose were observed using the secondary analyser. Conclusions: The novel Home OGTT device was reliable and easy to use and showed excellent agreement with two separate laboratory analysers. The Home OGTT offers potential as an effective alternative for clinic‐based OGTT testing. What's new?: This study evaluates the performance of a novel, pre‐production version of a home oral glucose tolerance testing (Home OGTT) device.The device was easy to use, with an excellent device success rate and showed good agreement with two separate laboratory analysers in both normal glucose tolerance and glucose intolerance.Our findings demonstrate that the device offers an alternative to clinic‐based OGTT testing, with the potential for the test to be performed conveniently at home or in a community setting.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N