Comparison of magnetization transfer contrast of conventional and simultaneous multislice turbo spin echo acquisitions focusing on excitation time interval.

Purpose: Image contrast differs between conventional multislice turbo spin echo (conventional TSE) and multiband turbo spin echo (SMS-TSE). Difference in time interval between excitations for adjacent slices (SETI) might cause this difference. This study aimed to evaluate the influence of SETI on MT...

Descripción completa

Detalles Bibliográficos
Publicado en:Japanese Journal of Radiology Vol. 37; no. 8; pp. 579 - 590
Autores principales: Murata, Syo, Tachibana, Yasuhiko, Murata, Katsutoshi, Kamagata, Koji, Hori, Masaaki, Andica, Christina, Suzuki, Michimasa, Wada, Akihiko, Kumamaru, Kanako, Hagiwara, Akifumi, Irie, Ryusuke, Sato, Shuji, Hamasaki, Nozomi, Fukunaga, Issei, Hoshito, Haruyoshi, Aoki, Shigeki
Formato: research Journal Article
Publicado: Springer Nature Aug2019
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=137588235&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 137588235
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        18671071
        AUCM
      jtl: Japanese Journal of Radiology
      issn: 18671071
      maglogo: N
    pubinfo:
      dt: Aug2019
      vid: 37
      iid: 8
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        137588235
        137588235
        NLM31230186
        137588235
        10.1007/s11604-019-00848-w
        NLM31230186
        137588235
      ppf: 579
      ppct: 11
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Comparison of magnetization transfer contrast of conventional and simultaneous multislice turbo spin echo acquisitions focusing on excitation time interval.
      aug:
        au:
          Murata, Syo
          Tachibana, Yasuhiko
          Murata, Katsutoshi
          Kamagata, Koji
          Hori, Masaaki
          Andica, Christina
          Suzuki, Michimasa
          Wada, Akihiko
          Kumamaru, Kanako
          Hagiwara, Akifumi
          Irie, Ryusuke
          Sato, Shuji
          Hamasaki, Nozomi
          Fukunaga, Issei
          Hoshito, Haruyoshi
          Aoki, Shigeki
        affil: Department of Radiology, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, 113-0033, Tokyo, Japan
      sug:
        subj:
          Image Processing, Computer Assisted Methods
          Brain Anatomy and Histology
          Magnetic Resonance Imaging Methods
          Human
          Male
          Adult
          Reproducibility of Results
          Phantoms, Imaging
          Validation Studies
          Comparative Studies
          Evaluation Research
          Multicenter Studies
          Adult: 19-44 years
          Male
      ab: Purpose: Image contrast differs between conventional multislice turbo spin echo (conventional TSE) and multiband turbo spin echo (SMS-TSE). Difference in time interval between excitations for adjacent slices (SETI) might cause this difference. This study aimed to evaluate the influence of SETI on MT effect for conventional TSE and compare conventional TSE with SMS-TSE in this respect.Materials and Methods: Three different agar concentration phantoms were scanned with conventional TSE by adjusting SETI and TR. Signal change for different SETI was evaluated using Pearson's correlation analysis. SMS-TSE was acquired by changing TR similarly. Three human volunteers were scanned with similar settings to evaluate reproducibility of the phantom results in human brain.Results: In conventional TSE, shorter SETI induced larger signal reduction. Longer TR and higher agar concentration emphasized this characteristic. Significant linear correlation (P < 0.05) was found in the major cases. The SMS-TSE signal intensity in each TR and phantom was smaller than the assumable levels in conventional TSE when the slices were simultaneously excited. Similar characteristic was observed in human brain.Conclusion: Shorter SETI results in larger MT effect in conventional TSE. The contrast change in SMS-TSE was larger than the supposable level from simultaneous excitation, which needs consideration in clinics.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N