X-ray examination dose surveys: how accurate are my results?

Objectives: To determine the variabilities of dose-area-products (DAP) of frequent X-ray examinations collected for comparison with diagnostic reference levels (DRLs).Methods: DAP values of chest, abdomen, and lumbar spine examinations obtained on devices from two manufacturers were collected in thr...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 29; no. 10; pp. 5307 - 5314
Autores principales: Taylor, Stephen, Van Muylem, Alain, Howarth, Nigel, Gevenois, Pierre Alain, Tack, Denis
Formato: research Journal Article
Publicado: Springer Nature Oct2019
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=138395921&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 138395921
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Oct2019
      vid: 29
      iid: 10
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        138395921
        138395921
        143976430
        NLM30877467
        138395921
        10.1007/s00330-019-06055-5
        NLM30877467
        138395921
      ppf: 5307
      ppct: 7
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: X-ray examination dose surveys: how accurate are my results?
      aug:
        au:
          Taylor, Stephen
          Van Muylem, Alain
          Howarth, Nigel
          Gevenois, Pierre Alain
          Tack, Denis
        affil: Department of Radiology, Hôpital Ambroise Paré, Boulevard Président Kennedy 2, 7000, Mons, Belgium
      sug:
        subj:
          Lumbar Vertebrae Radiation Effects
          Thorax Radiation Effects
          Abdomen Radiation Effects
          X-Rays
          Radiography Statistics and Numerical Data
          Reproducibility of Results
          Algorithms
          Sample Size
          Radiation Dosage
          Radiologic Health
          Physical Examination Methods
          Human
          Body Weight
          Validation Studies
          Comparative Studies
          Evaluation Research
          Multicenter Studies
      ab: Objectives: To determine the variabilities of dose-area-products (DAP) of frequent X-ray examinations collected for comparison with diagnostic reference levels (DRLs).Methods: DAP values of chest, abdomen, and lumbar spine examinations obtained on devices from two manufacturers were collected in three centers over 1 to 2 years. The variability of the average DAP results defined as the 95% confidence interval in percentage of their median value was calculated for increasing sample sizes, each examination and center. We computed the sample sizes yielding variabilities lower or equal to 25% and 10%. The effect of narrowing patient selection based on body weight was also investigated (ranges of 67-73 Kg, or 60-80 Kg).Results: DAP variabilities ranged from 75 to 170% of the median value when collecting small samples (10 to 20 DAP). To reduce this variability, larger samples are needed, collected over up to 2 years, regardless of the examination and center. A variability ≤ 10% could only be reached for chest X-rays, requiring up to 800 data. For the abdomen and lumbar spine, the lowest achievable variability was 25%, regardless of the body weight selection, requiring up to 400 data.Conclusion: Variabilities in DAP collected through small samples of ten data as recommended by authorities are very high, but can be reduced down to 25% (abdomen and lumbar spine) or even 10% (chest) through a substantial increase in sample sizes. Our findings could assist radiologists and regulatory authorities in estimating the reliability of the data obtained when performing X-ray dose surveys.Key Points: • Low but reasonable variabilities cannot be reached with samples sized as recommended by regulatory authorities. Higher numbers of DAP values are required to reduce the variability. • Variabilities of 10% for the chest and 25% for abdomen and lumbar spine examinations are achievable, provided large samples of data are collected over 1 year. • Our results could help radiologists and authorities interpret X-rays dose surveys.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N