Orthogonal cameras system for tracking of laparoscopic instruments in training environments.
Introduction: Motion analysis is a valuable tool for assessment of psychomotor skills in laparoscopy. Nonetheless, it requires technologies for tracking the activity of the laparoscopic instruments during training. This paper presents a sensor-free system to track the movements of laparoscopic instr...
| Publicado en: | Cirugía y Cirujanos Vol. 86; no. 6; pp. 548 - 556 |
|---|---|
| Autores principales: | , , , , , |
| Formato: | Artículo |
| Publicado: |
Publicidad Permanyer SLU
nov/dic2018
|
| Materias: | |
| Acceso en línea: | Ver este registro en EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=138804687&site=ehost-live header: @attributes: shortDbName: lth uiTerm: 138804687 longDbName: MedicLatina uiTag: AN controlInfo: bkinfo: jinfo: jid: 00097411 7KK jtl: Cirugía y Cirujanos issn: 00097411 maglogo: N pubinfo: dt: nov/dic2018 vid: 86 iid: 6 pid: 37650 pub: Publicidad Permanyer SLU artinfo: ui: 138804687 10.24875/CIRU.18000348 ppf: 548 ppct: 8 formats: tig: atl: Orthogonal cameras system for tracking of laparoscopic instruments in training environments. aug: au: Pérez-Escamirosa, Fernando Oropesa, Ignacio Sánchez-González, Patricia Tapia-Jurado, Jesús Ruiz-Lizarraga, Jorge Minor-Martínez, Arturo affil: Department of Surgery, Faculty of Medicine, Universidad Nacional Autónoma de México (UNAM), Ciudad de México, Mexico Biomedical Engineering and Telemedicine Centre (GBT), ETSI Telecomunicación, Center for Biomedical Technology, Universidad Politécnica de Madrid (UPM), Madrid, Spain Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Madrid, Spain Centro de Enseñanza por Simulación de Posgrado (CESIP), Unidad de Posgrado, Universidad Nacional Autónoma de México, Facultad de Medicina, Universidad Nacional Autónoma de México Ciudad de México, Mexico Department of Electrical Engineering, Bioelectronics Section, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Ciudad de México, Mexico su: Laparoscopy Training Motion analysis Psychomotor disorders Webcams sug: subj: Laparoscopy Training Motion analysis Psychomotor disorders Webcams keyword: Orthogonal cameras Triangulation Video-based tracking system Análisis de movimiento Cámaras ortogonales Laparoscopia Sistema de seguimiento en video Triangulación ab: Introduction: Motion analysis is a valuable tool for assessment of psychomotor skills in laparoscopy. Nonetheless, it requires technologies for tracking the activity of the laparoscopic instruments during training. This paper presents a sensor-free system to track the movements of laparoscopic instruments based on an orthogonal camera system and video image processing. Methods: The movements of the laparoscopic instruments are tracked with two webcams placed in an orthogonal configuration. The position and orientation in the three-dimensional workspace are obtained using color markers placed on the tip of the instruments. Results: Accuracy tests show a resolution of 0.14 mm for displacement, with 1694 cm3 of total workspace, and 0.54° in the angular movements. Mean relative errors of the tracking system were <1%. The orthogonal cameras show high precision, linearity, and repeatability of motion recording of the laparoscopic instruments. Conclusion: The proposed system offers unconstrained manipulation of the instruments and a low-cost alternative for traditional tracking technologies. Introducción: El análisis del movimiento es una valiosa herramienta para la evaluación de las habilidades psicomotrices en la laparoscopia. Sin embargo, requiere tecnologías para el seguimiento de la actividad de los instrumentos laparoscópicos durante el entrenamiento. En este artículo presentamos una técnica sin sensores para realizar el seguimiento de los movimientos de los instrumentos laparoscópicos basado en un sistema de cámara ortogonal y procesamiento de imágenes de video. Método: Los movimientos de los instrumentos laparoscópicos son capturados con dos cámaras web colocadas en configuración ortogonal. La posición y la orientación en el espacio de trabajo tridimensional se obtienen utilizando marcadores de color colocados en la punta de los instrumentos. Resultados: Las pruebas de precisión mostraron una resolución de 0.14 mm para el desplazamiento, con 1694 cm3 de espacio de trabajo total y 0.54° en los movimientos angulares. Los errores relativos medios del sistema de seguimiento fueron <1%. Las cámaras ortogonales demostraron alta precisión, linealidad y repetibilidad de la captura de movimiento de los instrumentos laparoscópicos. Conclusiones: El sistema propuesto ofrece una manipulación sin restricciones de los instrumentos laparoscópicos y una alternativa de bajo costo para las tecnologías tradicionales de captura de movimiento. pubtype: Academic Journal doctype: Article src: R language: English refInfo: copyright: @attributes: flag: Y dt: @attributes: year: 2018 holdings: @attributes: islocal: N |
|---|