Background: The pediatrics' chest X-rays using digital radiography are considered important because of the high rates of this test as well as the increased sensitivity of children to ionizing radiation compared with adults. Therefore, clarification of radiographic methods that reduce the dose and ma...

Descripción completa

Detalles Bibliográficos
Publicado en:Research in Medicine: Journal of Research in Medical Sciences Vol. 43; no. 3; pp. 150 - 157
Autores principales: فرشته رحمانی, محمدرضا دیوبند, زینب کاوه, بهزاد محسن زاده, الهه پیرایش
Formato: pictorial research tables/charts Journal Article
Publicado: Shahid Beheshti University of Medical Sciences 2019
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=139089923&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 139089923
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        17355311
        8UU0
      jtl: Research in Medicine: Journal of Research in Medical Sciences
      issn: 17355311
      maglogo: N
    pubinfo:
      dt: 2019
      vid: 43
      iid: 3
      pid: 27619
      pub: Shahid Beheshti University of Medical Sciences
      place: Tehran 198571743, <Blank>
    artinfo:
      ui:
        139089923
        139089923
        139089923
        139089923
      ppf: 150
      ppct: 7
      formats:
      tig:
        atl: طراحی و ساخت فانتوم همگن معادل قفسه سینه برای بررسی کیفیت تصویر در آزمون های رادیوگرافی قفسه سینه کودکان
      aug:
        au:
          فرشته رحمانی
          محمدرضا دیوبند
          زینب کاوه
          بهزاد محسن زاده
          الهه پیرایش
        affil: گروه فیزیک و مهندسی پزشکی،دانشکده پزشکی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران
      sug:
        subj:
          Equipment Design
          Radiography, Thoracic Methods
          Phantoms, Imaging Evaluation
          Radiation Dosage Evaluation
          Radiographic Image Enhancement Evaluation
          Pediatric Care
          Human
          Child
          Age Factors
          Computer Simulation
          Equipment Reliability
          Experimental Studies
          Child: 6-12 years
      ab: Background: The pediatrics' chest X-rays using digital radiography are considered important because of the high rates of this test as well as the increased sensitivity of children to ionizing radiation compared with adults. Therefore, clarification of radiographic methods that reduce the dose and maintain or even increase the quality of the image is of great importance and thus of interest to researchers. The goal of the present study was to build a chest equivalent homogeneous phantom to evaluate the image quality in radiographic tests in four age groups of children based on the ICRP103 age category classification. Materials and Methods: The X-ray spectrum approved by IPEM was used as the input x-ray source in the Monte Carlo code. The geometric phantom equivalent to the ORNL body was then simulated to calculate the absorb dose using Monte Carlo code. The results of the simulation were used to construct equivalent chest phantom for children. Results: In order to validate and verify the performance of the equivalent phantoms simulated for each age group, the attenuation and dispersion of the phantom at the field were measured. For this purpose, the percentages of the depth dose in the simulation conditions was compared with those of the experimental results, which can be used to examine the attenuation in different layers. The calculated error was less than 5% on the depth dose for the Monte Carlo and the experimental space and it indicates Confirmation of simulated program. After simulation, the phantom was made in similar dimensions with different thicknesses of the Plexiglas pediatrics age ranges. Conclusion: It seems that the phantom designed in the current study can be used to assess the doses of children in different age groups. It can also be used with local fitting for image quality control tools, such as contrast, resolution, etc, for evaluating the parameters related to the quality of the image in the actual condition.
      pubtype: Academic Journal
      doctype:
        pictorial
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: Persian
    refInfo:
    holdings:
      @attributes:
        islocal: N