Sparse sampling computed tomography (SpSCT) for detection of pulmonary embolism: a feasibility study.

Objectives: Evaluation of sparse sampling computed tomography (SpSCT) regarding subjective and objective image criteria for the detection of pulmonary embolism (PE) at different simulated dose levels.Methods: Computed tomography pulmonary angiography (CTPA) scans of 20 clinical patients were used to...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 29; no. 11; pp. 5950 - 5961
Autores principales: Sauter, Andreas P., Kopp, Felix K., Bippus, Rolf, Dangelmaier, Julia, Deniffel, Dominik, Fingerle, Alexander A., Meurer, Felix, Pfeiffer, Daniela, Proksa, Roland, Rummeny, Ernst J., Noël, Peter B.
Formato: research tables/charts Journal Article
Publicado: Springer Nature Nov2019
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=139163678&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 139163678
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: Nov2019
      vid: 29
      iid: 11
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        139163678
        139163678
        NLM31073861
        139163678
        10.1007/s00330-019-06217-5
        NLM31073861
        139163678
      ppf: 5950
      ppct: 11
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Sparse sampling computed tomography (SpSCT) for detection of pulmonary embolism: a feasibility study.
      aug:
        au:
          Sauter, Andreas P.
          Kopp, Felix K.
          Bippus, Rolf
          Dangelmaier, Julia
          Deniffel, Dominik
          Fingerle, Alexander A.
          Meurer, Felix
          Pfeiffer, Daniela
          Proksa, Roland
          Rummeny, Ernst J.
          Noël, Peter B.
        affil: Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany
      sug:
        subj:
          Pulmonary Embolism
          Radiation Dosage
          Pilot Studies
          Analysis of Variance
          Patient Safety
          Sensitivity and Specificity
          Artifacts
          Lung
          Human
          Funding Source
      ab: Objectives: Evaluation of sparse sampling computed tomography (SpSCT) regarding subjective and objective image criteria for the detection of pulmonary embolism (PE) at different simulated dose levels.Methods: Computed tomography pulmonary angiography (CTPA) scans of 20 clinical patients were used to obtain simulated low-dose scans with 100%-50%-25%-12.5%-6.3%-3.1% of the clinical dose, resulting in a total of six dose levels (DL). From these full sampling (FS) data, every second (2-SpSCT) or fourth (4-SpSCT) projection was used to obtain simulated sparse sampling scans. Each image set was evaluated by four blinded radiologists regarding subjective image criteria (artifacts, image quality) and diagnostic performance (confidence, sensitivity, specificity, accuracy, and area under the curve). Additionally, the contrast-to-noise ratio (CNR) was evaluated for objective image quality.Results: Sensitivity was 100% with 2-SpSCT and 4-SpSCT at the 25% DL and the 12.5% DL for all localizations of PE (one subgroup 98.5%). With FS, the sensitivity decreased to 90% at the 12.5% DL. 2-SpSCT and 4-SpSCT showed higher values for sensitivity, specificity, accuracy, and the area under the curve at all DL compared with FS. Subjective image quality was significantly higher for 4-SpSCT compared with FS at each dose level (p < 0.01, paired t test). Only with 4-SpSCT, all examinations were rated as showing diagnostic image quality at the 12.5% DL.Conclusions: Via SpSCT, a dose reduction down to a 12.5% dose level (corresponding to a mean effective dose of 0.38 mSv in the current study) for CTPA is possible while maintaining high image quality and full diagnostic confidence.Key Points: • With sparse sampling CT, radiation dose could be significantly reduced in clinical routine. • Sparse sampling CT is a novel hardware solution with which less projection images are acquired. • In the current study, a dose reduction of 87.5% (corresponding to a mean effective dose of 0.38 mSv) for CTPA could be achieved while maintaining excellent diagnostic performance.
      pubtype: Academic Journal
      doctype:
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N