Development and Validation of a Mobile Application for Measuring Femoral Anteversion in Patients With Cerebral Palsy.

Background: Computed tomography (CT) provides benefits for 3-dimensional (3D) visualization of femur deformities. However, the potential adverse effects of radiation exposure have become a concern. Consequently, a biplanar imaging system EOS has been proposed to enable reconstruction of the 3D model...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Pediatric Orthopaedics Vol. 39; no. 10
Autores principales: Sung, Ki Hyuk, Youn, Kibeom, Chung, Chin Youb, Kitta, Muhammad I, Kumara, Hendra C, Min, Jae Jung, Lee, Jehee, Park, Moon Seok
Formato: Journal Article
Publicado: Lippincott Williams & Wilkins Nov/Dec2019
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=139498385&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 139498385
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        02716798
        4CC
      jtl: Journal of Pediatric Orthopaedics
      issn: 02716798
      maglogo: N
    pubinfo:
      dt: Nov/Dec2019
      vid: 39
      iid: 10
      pid: 433
      pub: Lippincott Williams & Wilkins
      place: Baltimore, Maryland
    artinfo:
      ui:
        139498385
        139498385
        NLM31688821
        10.1097/BPO.0000000000001468
        NLM31688821
        139498385
      ppct: 1
      formats:
      tig:
        atl: Development and Validation of a Mobile Application for Measuring Femoral Anteversion in Patients With Cerebral Palsy.
      aug:
        au:
          Sung, Ki Hyuk
          Youn, Kibeom
          Chung, Chin Youb
          Kitta, Muhammad I
          Kumara, Hendra C
          Min, Jae Jung
          Lee, Jehee
          Park, Moon Seok
        affil: Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Sungnam, Gyeonggi Province
      sug:
      ab: Background: Computed tomography (CT) provides benefits for 3-dimensional (3D) visualization of femur deformities. However, the potential adverse effects of radiation exposure have become a concern. Consequently, a biplanar imaging system EOS has been proposed to enable reconstruction of the 3D model of the femur. However, this system requires a calibrated apparatus, the cost of which is high, and the area occupied by it is substantial. The purpose of this study was to develop a mobile application that included a new method of 3D reconstruction of the femur from conventional radiographic images and to evaluate the validity and reliability of mobile the application when measuring femoral anteversion.Methods: The statistical shape model, graph-cut algorithm, and iterative Perspective-n-Point algorithm were utilized to develop the application. The anteroposterior and lateral images of a femur can be input using the embedded camera or by file transfer, and the touch interface aids accurate contouring of the femur. Regarding validation, the CT scans and conventional radiographic images of 36 patients with cerebral palsy were used. To evaluate concurrent validity, the femoral anteversion measurements on the images reconstructed from the mobile application were compared with those from the 3D CT images. Three clinicians assessed interobserver reliability.Results: The mobile application, which reconstructs the 3D image from conventional radiographs, was successfully developed. Regarding concurrent validity, the correlation coefficient between femoral anteversion measured using 3D CT and the mobile application was 0.968 (P<0.001). In terms of interobserver reliability, the intraclass correlation coefficient among the 3 clinicians was 0.953.Conclusions: The measurement of femoral anteversion with the mobile application showed excellent concurrent validity and reliability in patients with cerebral palsy. The proposed mobile application can be used with conventional radiographs and does not require additional apparatus. It can be used as a convenient technique in hospitals that cannot afford a CT machine or an EOS system.Level Of Evidence: Level III-diagnostic.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N