Subject-specific finite element analysis of a lumbar cage produced by electron beam melting.

The aim of this study was the analysis of the mechanical behaviour of a partially porous lumbar custom-made cage by means of a subject-specific finite element analysis (FEA). The cage, made of Ti6Al4V ELI alloy, was produced via electron beam melting (EBM) process and surgically implanted in a femal...

Descripción completa

Detalles Bibliográficos
Publicado en:Medical & Biological Engineering & Computing Vol. 57; no. 12; pp. 2771 - 2782
Autores principales: Epasto, Gabriella, Distefano, Fabio, Mineo, Rosalia, Guglielmino, Eugenio
Formato: Journal Article
Publicado: Springer Nature Dec2019
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=140034799&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 140034799
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        01400118
        PO0
      jtl: Medical & Biological Engineering & Computing
      issn: 01400118
      maglogo: N
    pubinfo:
      dt: Dec2019
      vid: 57
      iid: 12
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        140034799
        140034799
        NLM31741290
        10.1007/s11517-019-02078-8
        NLM31741290
        140034799
      ppf: 2771
      ppct: 11
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Subject-specific finite element analysis of a lumbar cage produced by electron beam melting.
      aug:
        au:
          Epasto, Gabriella
          Distefano, Fabio
          Mineo, Rosalia
          Guglielmino, Eugenio
        affil: Department of Engineering, University of Messina, Contrada di Dio, Vill. Sant'Agata, 98166, Messina, Italy
      sug:
        subj:
          Lumbar Vertebrae Physiology
          Spinal Fusion Equipment and Supplies
          Female
          Spinal Fusion Methods
          Titanium
          Range of Motion Physiology
          Electrons
          Finite Element Analysis
          Internal Fixators
          Prostheses and Implants
          Kinematics Physiology
          Stress, Mechanical
          Physics
          Middle Age
          Clinical Assessment Tools
          Questionnaires
          Middle Aged: 45-64 years
          Female
      ab: The aim of this study was the analysis of the mechanical behaviour of a partially porous lumbar custom-made cage by means of a subject-specific finite element analysis (FEA). The cage, made of Ti6Al4V ELI alloy, was produced via electron beam melting (EBM) process and surgically implanted in a female subject, 50 years old. The novelty of this study was the customized design of the cage and of its internal structure, which is impossible to obtain with the traditional production techniques. The 3D model of the spine was obtained from the computed tomography (CT) of the patient. Moreover, high-resolution industrial CT was also used to reconstruct a 3D model of the cage, with its real (as-produced) features, such as superficial roughness, morphology of the bulk and of the porous structure. The workflow was divided in several steps: the main finite element analyses were non-linear and quasi-static regarding: the rhombic dodecahedron (RD) unit cell of the porous structure; the device; the whole L4-L5 motion segment with the implanted cage. Stress distribution was calculated under compression load for all models. For the RD unit cell, the maximum stress appeared at the connected cross nodes, where notch effect was present. For the cage subjected to a load of 1 kN, the porous structure did not present any functional failure. For the whole biomechanical system subjected to a physiological load of 360 N, the calculated stress in the bone was smaller than its yield strength value. On the axial view, a zone with higher compressive stresses was present on the L5 vertebral body. This was due to the contact stress between the cage and the vertebra. From the comparison between FE results and the CT images of the spine, bone remodelling was supposed, with the formation of new bone. Graphical abstract Workflow showing the phases of the research.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N