Ultrasound Assessment of Diaphragmatic Motion in Subjects With ARDS During Transpulmonary Pressure-Guided PEEP Titration.

BACKGROUND: We aimed to investigate the effects of incremental PEEP titration in patients with ARDS on regional diaphragmatic motion with bedside ultrasound. METHODS: Dorsal diaphragmatic excursion (DDE) and ventral diaphragmatic excursion (VDE) were measured using anatomic M-mode ultrasonography of...

Descripción completa

Detalles Bibliográficos
Publicado en:Respiratory Care Vol. 65; no. 3; pp. 314 - 320
Autores principales: Cho, Roy J., Adams, Alex, Ambur, Sum, Lunos, Scott, Shapiro, Robert, Prekker, Matthew E.
Formato: diagnostic images research tables/charts Journal Article
Publicado: Mary Ann Liebert, Inc. Mar2020
Acceso en línea:Ver este registro en EBSCOhost
Descripción
Sumario:BACKGROUND: We aimed to investigate the effects of incremental PEEP titration in patients with ARDS on regional diaphragmatic motion with bedside ultrasound. METHODS: Dorsal diaphragmatic excursion (DDE) and ventral diaphragmatic excursion (VDE) were measured using anatomic M-mode ultrasonography of the right hemidiaphragm as PEEP was randomized to -6, -3, -3, and -6 cm H2O from baseline to achieve a positive transpulmonary pressure. Inter-operator variability of DDE was assessed in 10 separate subjects. RESULTS: A total of 14 subjects ventilated for ARDS were enrolled. Subjects had a mean age of 54 ± 12 y, mean ... = 137 ± 54 mm Hg, and mean sequential organ failure assessment (SOFA) score = 14 ± 1). Transpulmonary pressure, DDE, and DDE/VDE ratio increased with incremental PEEP titration (-1.15cm H2O vs 3.63cm H2O, P < .001; 4.9 mm vs 8.2 mm, P < .001; and 62% vs 93%, P < .001, respectively). When transpulmonary pressure became positive, a visual increase in DDE and DDE/VDE ratio 0.60 to 0.93 was observed (from 0.48 cm to 0.82 cm, R² = 0.87, P = .02; and R² - 0.93, P = .006, respectively). There was high agreement in DDE measurements between 2 ultrasonographers (intra-class correlation 0.987, P < .001). CONCLUSIONS: DDE was affected by incremental PEEP titration toward a positive transpulmonary pressure. The ultrasound assessment using anatomic M-mode allowed for specific measurement of regional diaphragmatic excursion. This pattern of motion in the dependent regions of the diaphragm during PEEP titration in subjects with ARDS achieving a positive transpulmonary pressure may reflect a potential target for future studies in the bedside assessment for lung recruitment.