Test-retest reproducibility of a deep learning-based automatic detection algorithm for the chest radiograph.

Objectives: To perform test-retest reproducibility analyses for deep learning-based automatic detection algorithm (DLAD) using two stationary chest radiographs (CRs) with short-term intervals, to analyze influential factors on test-retest variations, and to investigate the robustness of DLAD to simu...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 30; no. 4; pp. 2346 - 2356
Autores principales: Kim, Hyungjin, Park, Chang Min, Goo, Jin Mo
Formato: research tables/charts Journal Article
Publicado: Springer Nature Apr2020
Acceso en línea:Ver este registro en EBSCOhost
Descripción
Sumario:Objectives: To perform test-retest reproducibility analyses for deep learning-based automatic detection algorithm (DLAD) using two stationary chest radiographs (CRs) with short-term intervals, to analyze influential factors on test-retest variations, and to investigate the robustness of DLAD to simulated post-processing and positional changes.Methods: This retrospective study included patients with pulmonary nodules resected in 2017. Preoperative CRs without interval changes were used. Test-retest reproducibility was analyzed in terms of median differences of abnormality scores, intraclass correlation coefficients (ICC), and 95% limits of agreement (LoA). Factors associated with test-retest variation were investigated using univariable and multivariable analyses. Shifts in classification between the two CRs were analyzed using pre-determined cutoffs. Radiograph post-processing (blurring and sharpening) and positional changes (translations in x- and y-axes, rotation, and shearing) were simulated and agreement of abnormality scores between the original and simulated CRs was investigated.Results: Our study analyzed 169 patients (median age, 65 years; 91 men). The median difference of abnormality scores was 1-2% and ICC ranged from 0.83 to 0.90. The 95% LoA was approximately ± 30%. Test-retest variation was negatively associated with solid portion size (β, - 0.50; p = 0.008) and good nodule conspicuity (β, - 0.94; p < 0.001). A small fraction (15/169) showed discordant classifications when the high-specificity cutoff (46%) was applied to the model outputs (p = 0.04). DLAD was robust to the simulated positional change (ICC, 0.984, 0.996), but relatively less robust to post-processing (ICC, 0.872, 0.968).Conclusions: DLAD was robust to the test-retest variation. However, inconspicuous nodules may cause fluctuations of the model output and subsequent misclassifications.Key Points: • The deep learning-based automatic detection algorithm was robust to the test-retest variation of the chest radiographs in general. • The test-retest variation was negatively associated with solid portion size and good nodule conspicuity. • High-specificity cutoff (46%) resulted in discordant classifications of 8.9% (15/169; p = 0.04) between the test-retest radiographs.