In vivo three-dimensional evaluation of tumour hypoxia in nasopharyngeal carcinomas using FMT-CT and MSOT.

Purpose: Accurate evaluation of hypoxia is particularly important in patients with nasopharyngeal carcinoma (NPC) undergoing radiotherapy. The aim of this study was to propose a novel imaging strategy for quantitative three-dimensional (3D) evaluation of hypoxia in a small animal model of NPC. Metho...

Descripción completa

Detalles Bibliográficos
Publicado en:European Journal of Nuclear Medicine & Molecular Imaging Vol. 47; no. 5; pp. 1027 - 1039
Autores principales: Huang, Wenhui, Wang, Kun, An, Yu, Meng, Hui, Gao, Yuan, Xiong, Zhiyuan, Yan, Hao, Wang, Qian, Cai, Xuekang, Yang, Xin, Zhang, Bin, Chen, Qiuying, Yang, Xing, Tian, Jie, Zhang, Shuixing
Formato: Journal Article
Publicado: Springer Nature May2020
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=142435953&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 142435953
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        16197070
        NPC
      jtl: European Journal of Nuclear Medicine & Molecular Imaging
      issn: 16197070
      maglogo: N
    pubinfo:
      dt: May2020
      vid: 47
      iid: 5
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        142435953
        10.1007/s00259-019-04526-x
        142435953
      ppf: 1027
      ppct: 12
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: In vivo three-dimensional evaluation of tumour hypoxia in nasopharyngeal carcinomas using FMT-CT and MSOT.
      aug:
        au:
          Huang, Wenhui
          Wang, Kun
          An, Yu
          Meng, Hui
          Gao, Yuan
          Xiong, Zhiyuan
          Yan, Hao
          Wang, Qian
          Cai, Xuekang
          Yang, Xin
          Zhang, Bin
          Chen, Qiuying
          Yang, Xing
          Tian, Jie
          Zhang, Shuixing
        affil: Medical Imaging Center, the First Affiliated Hospital, Jinan University, No. 163, Huangpu West Road, Tianhe District, 510632, Guangzhou, Guangdong, China
      sug:
      ab: Purpose: Accurate evaluation of hypoxia is particularly important in patients with nasopharyngeal carcinoma (NPC) undergoing radiotherapy. The aim of this study was to propose a novel imaging strategy for quantitative three-dimensional (3D) evaluation of hypoxia in a small animal model of NPC. Methods: A carbonic anhydrase IX (CAIX)-specific molecular probe (CAIX-800) was developed for imaging of hypoxia. Mouse models of subcutaneous, orthotopic, and spontaneous lymph node metastasis from NPC (5 mice per group) were established to assess the imaging strategy. A multi-modality imaging method that consisted of a hybrid combination of fluorescence molecular tomography-computed tomography (FMT-CT) and multispectral optoacoustic tomography (MSOT) was used for 3D quantitative evaluation of tumour hypoxia. Magnetic resonance imaging, histological examination, and immunohistochemical analysis were used as references for comparison and validation. Results: In the early stage of NPC (2 weeks after implantation), FMT-CT enabled precise 3D localisation of the hypoxia biomarker with high sensitivity. At the advanced stage (6 weeks after implantation), MSOT allowed multispectral analysis of the biomarker and haemoglobin molecules with high resolution. The combination of high sensitivity and high resolution from FMT-CT and MSOT could not only detect hypoxia in small-sized NPCs but also visualise the heterogeneity of hypoxia in 3D. Conclusions: Integration of FMT-CT and MSOT could allow comprehensive and quantifiable evaluation of hypoxia in NPC. These findings may potentially benefit patients with NPC undergoing radiotherapy in the future.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N