Investigating multiple sources of data for smart infusion pump and electronic health record interoperability.
Purpose Infusion pump data, which describe compliance to dose-error reduction software among other metrics, are retrievable from infusion pump vendor software, electronic health record (EHR) systems, and regional and national data repositories such as the Regenstrief National Center for Medical Devi...
| Publicado en: | American Journal of Health-System Pharmacy Vol. 77; no. 17; pp. 1417 - 1424 |
|---|---|
| Autores principales: | , , , , , , , , , |
| Formato: | tables/charts Journal Article |
| Publicado: |
Oxford University Press / USA
Sep2020
|
| Acceso en línea: | Ver este registro en EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=145254417&site=ehost-live header: @attributes: shortDbName: ccm uiTerm: 145254417 longDbName: CINAHL Complete uiTag: AN controlInfo: bkinfo: dissinfo: jinfo: jid: 10792082 1X3 jtl: American Journal of Health-System Pharmacy issn: 10792082 maglogo: N pubinfo: dt: Sep2020 vid: 77 iid: 17 pid: 622 pub: Oxford University Press / USA artinfo: ui: 145254417 145254417 145254417 10.1093/ajhp/zxaa115 145254417 ppf: 1417 ppct: 7 formats: fmt: – @attributes: type: T – @attributes: type: P tig: atl: Investigating multiple sources of data for smart infusion pump and electronic health record interoperability. aug: au: Marwitz, Kathryn K Fritschle, Andrew C Trivedi, Vivek Covert, Matthew L Walroth, Todd A DeLaurentis, Poching Saunders, Taren Walleser, Nathan Fuller, James Degnan, Dan affil: Manchester University College of Pharmacy, Natural, and Health Sciences , Fort Wayne, IN sug: subj: Infusion Pumps Electronic Health Records Information Retrieval Information Storage Medication Errors Prevention and Control Data Analytics Patient Safety Evaluation Decision Support Systems, Clinical Collaboration Benchmarking Medical Informatics ab: Purpose Infusion pump data, which describe compliance to dose-error reduction software among other metrics, are retrievable from infusion pump vendor software, electronic health record (EHR) systems, and regional and national data repositories such as the Regenstrief National Center for Medical Device Informatics (REMEDI). Smart infusion pump and EHR interoperability has added to the granularity and complexity of data collected, and clinicians are challenged with efficiently comprehending and interpreting the data and reports available. Summary Collaborative partnerships between the Indianapolis Coalition for Patient Safety and the Regenstrief Center for Healthcare Engineering allowed for clinicians, informaticists, researchers, and engineers to compare the information gained and strengths of using smart infusion pumps, EHR, and REMEDI to assess hospital medication safety in a setting of interoperability. Seven reporting capabilities were used to compare available reports, and 2 hypothetical scenarios were developed to highlight these processes. Infusion pump vendor–provided software and reports were found to provide the most usable information for detailed infusion reporting, while the EHR was strongly usable for interoperability compliance and REMEDI excelled in benchmarking capabilities. Conclusion While infusion analytics needs may differ across health systems, a better understanding of the strengths of infusion pump data and EHR data may help provide structure and direction in the infusion analytics process. Infusion data repositories such as REMEDI are useful tools to obtain information in a way not delivered by smart pump data. pubtype: Academic Journal doctype: tables/charts Journal Article ougenre: Article language: English refInfo: holdings: @attributes: islocal: N |
|---|