Monitoring tissue perfusion: a pilot clinical feasibility and safety study of a urethral photoplethysmography-derived perfusion device in high-risk patients.

Continuous monitoring of tissue perfusion in patients with hemodynamic instability remains challenging because of the lack of tools available. Through using urethral photoplethysmography, the urethral perfusion index (uPI) could allow tissue perfusion monitoring through a modified urinary catheter....

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Clinical Monitoring & Computing Vol. 34; no. 5; pp. 961 - 970
Autores principales: Dépret, François, Leone, Marc, Duclos, Gary, Futier, Emmanuel, Montagne, Maxime, Legrand, Matthieu, Allaouchiche, Bernard
Formato: research Journal Article
Publicado: Springer Nature Oct2020
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=145302262&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 145302262
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        13871307
        OHC
      jtl: Journal of Clinical Monitoring & Computing
      issn: 13871307
      maglogo: N
    pubinfo:
      dt: Oct2020
      vid: 34
      iid: 5
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        145302262
        145302262
        NLM31691897
        145302262
        10.1007/s10877-019-00414-9
        NLM31691897
        145302262
      ppf: 961
      ppct: 9
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Monitoring tissue perfusion: a pilot clinical feasibility and safety study of a urethral photoplethysmography-derived perfusion device in high-risk patients.
      aug:
        au:
          Dépret, François
          Leone, Marc
          Duclos, Gary
          Futier, Emmanuel
          Montagne, Maxime
          Legrand, Matthieu
          Allaouchiche, Bernard
        affil: Department of Anesthesiology and Critical Care and Burn Unit, AP-HP, GH St-Louis-Lariboisière, Paris, France
      sug:
        subj:
          Urethra
          Plethysmography
          Male
          Human
          Perfusion
          Prospective Studies
          Pilot Studies
          Adolescence
          Comparative Studies
          Multicenter Studies
          Evaluation Research
          Validation Studies
          Scales
          Ferrans and Powers Quality of Life Index
          Adolescent: 13-18 years
          Male
      ab: Continuous monitoring of tissue perfusion in patients with hemodynamic instability remains challenging because of the lack of tools available. Through using urethral photoplethysmography, the urethral perfusion index (uPI) could allow tissue perfusion monitoring through a modified urinary catheter. The first objective of our study was to evaluate the feasibility and safety of the IKORUS UP (Advanced Perfusion Diagnostics, Villeurbanne, France), a new device in the field. The secondary objectives were to evaluate the performance (duration and signal quality) of the IKORUS UP probe and to assess the uPI variations during hemodynamic events during major abdominal surgery. "STEP UP" was a prospective, multicenter, observational study. The inclusion criteria were age 18 years or older with signed informed consent and admitted to intensive care unit (ICU) with hemodynamic instability or high-risk surgical patient. Thirty patients were included in the study, 26 in the operating room, and four in the ICU. Of these patients, 28 were analyzed. For the primary outcome, six (21%) patients had pain scores assessed at insertion of and 22 (79%) at withdrawal of the catheter. The mean EVA score was 1.5 (IQ 1-2) and 0.7 (IQ 0-1), respectively, with the highest score being 3. One (4%) minor urethral bleeding and one (4%) catheter-associated urinary tract infection were reported. The IKORUS UP probe remained in the urethra for an average of 172 h (IQ40-328). The median signal measurement time was 33 h (IQ 5.2-46). The signal quality was recorded as good or excellent for 99% (IQ 82-100) of the insertion duration. The signal quality index was 93% (IQ 87-96) with a signal-to-noise ratio of 26 (IQ 21-36). We observed clinically relevant variations in the uPI over time during hemodynamic events or therapeutic interventions, with a strong cross-correlation with macrohemodynamic variables in some patients, while others did not display macrohemodynamic changes. The IKORUS UP probe was well tolerated and allowed urethral perfusion monitoring. Clinically relevant changes in tissue perfusion could be recorded during the observational period. Trial Registration: ( www.clinicaltrials.gov NCT03410069) registered January 25, 2018.
      pubtype: Academic Journal
      doctype:
        research
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N