Left ventricle automatic pacing threshold management in CRT systems: A comprehensive review.

Modern cardiac resynchronization therapy (CRT) device‐based threshold detection enables capture management and voltage output adjusting to combine consistent left ventricular (LV) pacing with acceptable battery drainage. The current technologies available for LV capture automatic confirmation in mos...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Cardiovascular Electrophysiology Vol. 31; no. 9; pp. 2489 - 2499
Autores principales: Zoppo, Franco, Gagno, Giulia
Formato: pictorial review tables/charts tracings Journal Article
Publicado: Wiley-Blackwell Sep2020
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=145514065&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 145514065
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10453873
        GSB
      jtl: Journal of Cardiovascular Electrophysiology
      issn: 10453873
      maglogo: Y
    pubinfo:
      dt: Sep2020
      vid: 31
      iid: 9
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        145514065
        145514065
        145789973
        145514065
        10.1111/jce.14630
        145514065
      ppf: 2489
      ppct: 10
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: C
          – @attributes:
              type: P
      tig:
        atl: Left ventricle automatic pacing threshold management in CRT systems: A comprehensive review.
      aug:
        au:
          Zoppo, Franco
          Gagno, Giulia
        affil: Cardiology Unit—Public Hospital of Gorizia, Giuliano‐Isontina Health—University Authority (ASUGI), Gorizia, Italy
      sug:
        subj:
          Heart Ventricle Physiology
          Cardiac Pacing, Artificial
          Disease Management
          Cardiac Resynchronization Therapy Methods
          Evoked Potentials
          Algorithms
      ab: Modern cardiac resynchronization therapy (CRT) device‐based threshold detection enables capture management and voltage output adjusting to combine consistent left ventricular (LV) pacing with acceptable battery drainage. The current technologies available for LV capture automatic confirmation in most cases require the evoked response, as well as "LV pace to right ventricular sense" algorithms. The LV pacing percentage counter may overestimate the CRT delivery which may be reduced due to pacing inhibition (by sensed LV activation) or inadequate capture due to subthreshold current or pacing into refractory tissue. Moreover, the LV threshold at implant and its behavior over time (as a marker of electrical viability) and the ineffective CRT issues (subthreshold stimulation or concealed loss of capture) are discussed. The purpose of the present review is to explore these new challenges regarding LV pacing automatic management.