A Comparison of T2 Relaxation-Based MRI Stroke Timing Methods in Hyperacute Ischemic Stroke Patients: A Pilot Study.

Background: T2 relaxation-based magnetic resonance imaging (MRI) signals may provide onset time for acute ischemic strokes with an unknown onset. The ability of visual and quantitative MRI-based methods in a cohort of hyperacute ischemic stroke patients was studied. Methods: A total of 35 patients u...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Central Nervous System Disease pp. 1 - 14
Autores principales: McGarry, Bryony L, Damion, Robin A, Chew, Isabel, Knight, Michael J, Harston, George WJ, Carone, Davide, Jezzard, Peter, Sitaram, Amith, Muir, Keith W, Clatworthy, Philip, Kauppinen, Risto A
Formato: diagnostic images equations & formulas research tables/charts Journal Article
Publicado: Sage Publications Inc. 9/12/2020
Acceso en línea:Ver este registro en EBSCOhost
Descripción
Sumario:Background: T2 relaxation-based magnetic resonance imaging (MRI) signals may provide onset time for acute ischemic strokes with an unknown onset. The ability of visual and quantitative MRI-based methods in a cohort of hyperacute ischemic stroke patients was studied. Methods: A total of 35 patients underwent 3T (3 Tesla) MRI (<9-hour symptom onset). Diffusion-weighted (DWI), apparent diffusion coefficient (ADC), T1-weighted (T1w), T2-weighted (T2w), and T2 relaxation time (T2) images were acquired. T2-weighted fluid attenuation inversion recovery (FLAIR) images were acquired for 17 of these patients. Image intensity ratios of the average intensities in ischemic and non-ischemic reference regions were calculated for ADC, DWI, T2w, T2 relaxation, and FLAIR images, and optimal image intensity ratio cut-offs were determined. DWI and FLAIR images were assessed visually for DWI/FLAIR mismatch. Results: The T2 relaxation time image intensity ratio was the only parameter with significant correlation with stroke duration (r = 0.49, P =.003), an area under the receiver operating characteristic curve (AUC = 0.77, P <.0001), and an optimal cut-off (T2 ratio = 1.072) that accurately identified patients within the 4.5-hour thrombolysis treatment window with sensitivity of 0.74 and specificity of 0.74. In the patients with the additional FLAIR, areas under the precision-recall-gain curve (AUPRG) and F1 scores showed that the T2 relaxation time ratio (AUPRG = 0.60, F1 = 0.73) performed considerably better than the FLAIR ratio (AUPRG = 0.39, F1 = 0.57) and the visual DWI/FLAIR mismatch (F1 = 0.25). Conclusions: Quantitative T2 relaxation time is the preferred MRI parameter in the assessment of patients with unknown onset for treatment stratification.