Simultaneous Mapping of T1 and T2 Using Cardiac Magnetic Resonance Fingerprinting in a Cohort of Healthy Subjects at 1.5T.

Background: Cardiac MR fingerprinting (cMRF) is a novel technique for simultaneous T1 and T2 mapping.Purpose: To compare T1 /T2 measurements, repeatability, and map quality between cMRF and standard mapping techniques in healthy subjects.Study Type: Prospective.Population: In all, 58 subjects (ages...

Descripción completa

Detalles Bibliográficos
Publicado en:Journal of Magnetic Resonance Imaging Vol. 52; no. 4; pp. 1044 - 1053
Autores principales: Hamilton, Jesse I., Pahwa, Shivani, Adedigba, Joseph, Frankel, Samuel, O'Connor, Gregory, Thomas, Rahul, Walker, Jonathan R., Killinc, Ozden, Lo, Wei‐Ching, Batesole, Joshua, Margevicius, Seunghee, Griswold, Mark, Rajagopalan, Sanjay, Gulani, Vikas, Seiberlich, Nicole, Lo, Wei-Ching
Formato: diagnostic images research tables/charts Journal Article
Publicado: Wiley-Blackwell Oct2020
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=145731943&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 145731943
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        10531807
        O63
      jtl: Journal of Magnetic Resonance Imaging
      issn: 10531807
      maglogo: Y
    pubinfo:
      dt: Oct2020
      vid: 52
      iid: 4
      pid: 480
      pub: Wiley-Blackwell
      place: Malden, Massachusetts
    artinfo:
      ui:
        145731943
        145731943
        NLM32222092
        145731943
        10.1002/jmri.27155
        NLM32222092
        145731943
      ppf: 1044
      ppct: 9
      formats:
      tig:
        atl: Simultaneous Mapping of T1 and T2 Using Cardiac Magnetic Resonance Fingerprinting in a Cohort of Healthy Subjects at 1.5T.
      aug:
        au:
          Hamilton, Jesse I.
          Pahwa, Shivani
          Adedigba, Joseph
          Frankel, Samuel
          O'Connor, Gregory
          Thomas, Rahul
          Walker, Jonathan R.
          Killinc, Ozden
          Lo, Wei‐Ching
          Batesole, Joshua
          Margevicius, Seunghee
          Griswold, Mark
          Rajagopalan, Sanjay
          Gulani, Vikas
          Seiberlich, Nicole
          Lo, Wei-Ching
        affil: Department of Radiology, University of Michigan, Ann Arbor Michigan,, USA
      sug:
        subj:
          Heart
          Magnetic Resonance Imaging
          Adolescence
          Adult
          Middle Age
          Young Adult
          Human
          Reproducibility of Results
          Magnetic Resonance Spectroscopy
          Prospective Studies
          Research Subjects
          Phantoms, Imaging
          Comparative Studies
          Multicenter Studies
          Evaluation Research
          Validation Studies
          Funding Source
          Adolescent: 13-18 years
          Adult: 19-44 years
          Middle Aged: 45-64 years
      ab: Background: Cardiac MR fingerprinting (cMRF) is a novel technique for simultaneous T1 and T2 mapping.Purpose: To compare T1 /T2 measurements, repeatability, and map quality between cMRF and standard mapping techniques in healthy subjects.Study Type: Prospective.Population: In all, 58 subjects (ages 18-60). FIELD STRENGTH/SEQUENCE: cMRF, modified Look-Locker inversion recovery (MOLLI), and T2 -prepared balanced steady-state free precession (bSSFP) at 1.5T.Assessment: T1 /T2 values were measured in 16 myocardial segments at apical, medial, and basal slice positions. Test-retest and intrareader repeatability were assessed for the medial slice. cMRF and conventional mapping sequences were compared using ordinal and two alternative forced choice (2AFC) ratings.Statistical Tests: Paired t-tests, Bland-Altman analyses, intraclass correlation coefficient (ICC), linear regression, one-way analysis of variance (ANOVA), and binomial tests.Results: Average T1 measurements were: basal 1007.4±96.5 msec (cMRF), 990.0±45.3 msec (MOLLI); medial 995.0±101.7 msec (cMRF), 995.6±59.7 msec (MOLLI); apical 1006.6±111.2 msec (cMRF); and 981.6±87.6 msec (MOLLI). Average T2 measurements were: basal 40.9±7.0 msec (cMRF), 46.1±3.5 msec (bSSFP); medial 41.0±6.4 msec (cMRF), 47.4±4.1 msec (bSSFP); apical 43.5±6.7 msec (cMRF), 48.0±4.0 msec (bSSFP). A statistically significant bias (cMRF T1 larger than MOLLI T1 ) was observed in basal (17.4 msec) and apical (25.0 msec) slices. For T2 , a statistically significant bias (cMRF lower than bSSFP) was observed for basal (-5.2 msec), medial (-6.3 msec), and apical (-4.5 msec) slices. Precision was lower for cMRF-the average of the standard deviation measured within each slice was 102 msec for cMRF vs. 61 msec for MOLLI T1 , and 6.4 msec for cMRF vs. 4.0 msec for bSSFP T2 . cMRF and conventional techniques had similar test-retest repeatability as quantified by ICC (0.87 cMRF vs. 0.84 MOLLI for T1 ; 0.85 cMRF vs. 0.85 bSSFP for T2 ). In the ordinal image quality comparison, cMRF maps scored higher than conventional sequences for both T1 (all five features) and T2 (four features).Data Conclusion: This work reports on myocardial T1 /T2 measurements in healthy subjects using cMRF and standard mapping sequences. cMRF had slightly lower precision, similar test-retest and intrareader repeatability, and higher scores for map quality.Evidence Level: 2 TECHNICAL EFFICACY: Stage 1 J. Magn. Reson. Imaging 2020;52:1044-1052.
      pubtype: Academic Journal
      doctype:
        diagnostic images
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N