Torque estimation based on surface electromyography: potential tool for knee rehabilitation.
Introduction: Multiple signal processing studies have reported the application of surface electromyography (sEMG) signals in robotics and motor rehabilitation processes. Objective: To conduct a literature review on the use of sEMG signals as an alternative method for knee torque estimation in order...
| Published in: | Revista Facultad de Medicina de la Universidad Nacional de Colombia Vol. 68; no. 3; pp. 438 - 446 |
|---|---|
| Main Authors: | , , , |
| Format: | Article |
| Published: |
Universidad Nacional de Colombia
jul-sep2020
|
| Subjects: | |
| Online Access: | View this record in EBSCOhost |
| fields | @attributes: recordID: 1 pdfLink: plink: https://search.ebscohost.com/login.aspx?direct=true&db=lth&AN=146986287&site=ehost-live header: @attributes: shortDbName: lth uiTerm: 146986287 longDbName: MedicLatina uiTag: AN controlInfo: bkinfo: jinfo: jid: 01200011 78E0 jtl: Revista Facultad de Medicina de la Universidad Nacional de Colombia issn: 01200011 maglogo: N pubinfo: dt: jul-sep2020 vid: 68 iid: 3 pid: 12967 pub: Universidad Nacional de Colombia artinfo: ui: 146986287 10.15446/revfacmed.v68n3.75214 ppf: 438 ppct: 8 formats: fmt: @attributes: type: P size: 767KB tig: atl: Torque estimation based on surface electromyography: potential tool for knee rehabilitation. aug: au: Andrés Portela, Mario Irina Sánchez-Romero, Juanita Zasúlich Pérez, Vera José Betancur, Manuel affil: Universidad Pontificia Bolivariana - Faculty of Electrical and Electronic Engineering - Bioengineering Research Group - Medellín - Colombia Universidad Pontificia Bolivariana - Faculty of Electrical and Electronic Engineering - A+D Automatic and Design Group - Medellín - Colombia su: Institute of Electrical & Electronics Engineers Surface potential Torque Knee Rehabilitation Signal processing sug: subj: Institute of Electrical & Electronics Engineers Surface potential Torque Knee Rehabilitation Signal processing keyword: Electromyography Knee Joint Muscle Contraction (MeSH) Articulación de la rodilla Contracción muscular (DeCS) Electromiografía ab: Introduction: Multiple signal processing studies have reported the application of surface electromyography (sEMG) signals in robotics and motor rehabilitation processes. Objective: To conduct a literature review on the use of sEMG signals as an alternative method for knee torque estimation in order to objectively measure the progress of patients at different stages of knee injury rehabilitation. Materials and methods: A literature review of studies published between 1986 and 2018, without geographical limits, was carried out in the Engineering Village, IEEE Xplore, Science- Direct, Web of Science, Scopus, and PubMed databases by combining 8 search terms. Results: After completing the initial search, 355 records were retrieved. Duplicated publications were eliminated, and 308 articles were analyzed to determine if they met the inclusion criteria. Finally, 18 studies describing, in a comparative way, how to estimate torque based on sEMG signals were included. Conclusion: The use of sEMG signals to calculate joint torque is an alternative method that allows therapists to obtain quantitative parameters and assess the progress of patients undergoing knee rehabilitation processes. Introducción. Múltiples estudios de procesamiento de señales han reportado la aplicación de las señales de electromiografía de superficie (sEMG) en robótica y en procesos de rehabilitación motora. Objetivo. Realizar una revisión de la literatura sobre el uso de señales de sEMG como alternativa para la estimación del par de rodilla con el fin de medir objetivamente el progreso de los pacientes en las diferentes etapas de rehabilitación de lesiones de rodilla. Materiales y métodos. Se realizó una revisión de la literatura publicada entre 1986 y 2018, sin límites geográficos, en las bases de datos Engineering Village, IEEE Xplore, ScienceDirect, Web of Science, Scopus y PubMed mediante la combinación de 8 términos de búsqueda. Resultados. Al finalizar la búsqueda inicial se obtuvieron 355 registros. Luego de realizar la remoción de duplicados esta cifra descendió a 308, los cuales fueron analizados para determinar si cumplían con los criterios de inclusión. Finalmente se incluyeron 18 estudios que describen de forma comparativa cómo estimar el par a partir de señales de sEMG. Conclusión. El uso de señales de sEMG para calcular el par en una articulación es una herramienta alternativa que permite al terapeuta acceder a parámetros cuantitativos y, de esta forma, valorar el progreso de los pacientes durante el proceso de rehabilitación de rodilla. pubtype: Academic Journal doctype: Article src: R language: English refInfo: copyright: @attributes: flag: Y custom: Copyright of Revista Facultad de Medicina de la Universidad Nacional de Colombia is the property of Universidad Nacional de Colombia and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. item: Revista Facultad de Medicina de la Universidad Nacional de Colombia holder: Universidad Nacional de Colombia dt: @attributes: year: 2020 holdings: @attributes: islocal: N |
|---|