Augmented deep learning model for improved quantitative accuracy of MR-based PET attenuation correction in PSMA PET-MRI prostate imaging.

Purpose: Estimation of accurate attenuation maps for whole-body positron emission tomography (PET) imaging in simultaneous PET-MRI systems is a challenging problem as it affects the quantitative nature of the modality. In this study, we aimed to improve the accuracy of estimated attenuation maps fro...

Descripción completa

Detalles Bibliográficos
Publicado en:European Journal of Nuclear Medicine & Molecular Imaging Vol. 48; no. 1; pp. 9 - 21
Autores principales: Pozaruk, Andrii, Pawar, Kamlesh, Li, Shenpeng, Carey, Alexandra, Cheng, Jeremy, Sudarshan, Viswanath P., Cholewa, Marian, Grummet, Jeremy, Chen, Zhaolin, Egan, Gary
Formato: Journal Article
Publicado: Springer Nature 2021
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=148321526&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 148321526
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        16197070
        NPC
      jtl: European Journal of Nuclear Medicine & Molecular Imaging
      issn: 16197070
      maglogo: N
    pubinfo:
      dt: 2021
      vid: 48
      iid: 1
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        148321526
        144055290
        10.1007/s00259-020-04816-9
        148321526
      ppf: 9
      ppct: 12
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Augmented deep learning model for improved quantitative accuracy of MR-based PET attenuation correction in PSMA PET-MRI prostate imaging.
      aug:
        au:
          Pozaruk, Andrii
          Pawar, Kamlesh
          Li, Shenpeng
          Carey, Alexandra
          Cheng, Jeremy
          Sudarshan, Viswanath P.
          Cholewa, Marian
          Grummet, Jeremy
          Chen, Zhaolin
          Egan, Gary
        affil: Monash Biomedical Imaging, Monash University, Building 220, Clayton Campus, 770 Blackburn Rd, 3168, Clayton, Victoria, Australia
      sug:
      ab: Purpose: Estimation of accurate attenuation maps for whole-body positron emission tomography (PET) imaging in simultaneous PET-MRI systems is a challenging problem as it affects the quantitative nature of the modality. In this study, we aimed to improve the accuracy of estimated attenuation maps from MRI Dixon contrast images by training an augmented generative adversarial network (GANs) in a supervised manner. We augmented the GANs by perturbing the non-linear deformation field during image registration between MRI and the ground truth CT images. Methods: We acquired the CT and the corresponding PET-MR images for a cohort of 28 prostate cancer patients. Data from 18 patients (2160 slices and later augmented to 270,000 slices) was used for training the GANs and others for validation. We calculated the error in bone and soft tissue regions for the AC μ-maps and the reconstructed PET images. Results: For quantitative analysis, we use the average relative absolute errors and validate the proposed technique on 10 patients. The DL-based MR methods generated the pseudo-CT AC μ-maps with an accuracy of 4.5% more than standard MR-based techniques. Particularly, the proposed method demonstrates improved accuracy in the pelvic regions without affecting the uptake values. The lowest error of the AC μ-map in the pelvic region was 1.9% for μ-mapGAN + aug compared with 6.4% for μ-mapdixon, 5.9% for μ-mapdixon + bone, 2.1% for μ-mapU-Net and 2.0% for μ-mapU-Net + aug. For the reconstructed PET images, the lowest error was 2.2% for PETGAN + aug compared with 10.3% for PETdixon, 8.7% for PETdixon + bone, 2.6% for PETU-Net and 2.4% for PETU-Net + aug.. Conclusion: The proposed technique to augment the training datasets for training of the GAN results in improved accuracy of the estimated μ-map and consequently the PET quantification compared to the state of the art.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N