Technical success rates and reliability of spin-echo echo-planar imaging (SE-EPI) MR elastography in patients with chronic liver disease or liver cirrhosis.

Objectives: To determine the technical success rates of MR elastography (MRE) according to established gradient-recalled echo (GRE) and spin-echo echo-planar imaging (SE-EPI) sequences and to compare liver stiffness (LS) values between the sequences during expiratory and inspiratory phases in patien...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 30; no. 3; pp. 1730 - 1738
Autores principales: Choi, Sang Lim, Lee, Eun Sun, Ko, Ara, Park, Hyun Jeong, Park, Sung Bin, Choi, Byung Ihn, Cho, Young Youn, Kannengiesser, Stephan
Formato: diagnostic images research tables/charts Journal Article
Publicado: Springer Nature 2020
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=148390813&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 148390813
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: 2020
      vid: 30
      iid: 3
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        148390813
        148390813
        NLM31728687
        148390813
        10.1007/s00330-019-06496-y
        NLM31728687
        148390813
      ppf: 1730
      ppct: 8
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: Technical success rates and reliability of spin-echo echo-planar imaging (SE-EPI) MR elastography in patients with chronic liver disease or liver cirrhosis.
      aug:
        au:
          Choi, Sang Lim
          Lee, Eun Sun
          Ko, Ara
          Park, Hyun Jeong
          Park, Sung Bin
          Choi, Byung Ihn
          Cho, Young Youn
          Kannengiesser, Stephan
        affil: Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, 102, Heukseok-ro, Dongjak-gu, 06973, Seoul, Republic of Korea
      sug:
        subj:
          Liver Cirrhosis Diagnosis
          Magnetic Resonance Imaging Methods
          Liver
          Male
          Middle Age
          Adult
          Reproducibility of Results
          Retrospective Design
          Female
          Liver Diseases Diagnosis
          Human
          Middle Aged: 45-64 years
          Adult: 19-44 years
          Male
          Female
      ab: Objectives: To determine the technical success rates of MR elastography (MRE) according to established gradient-recalled echo (GRE) and spin-echo echo-planar imaging (SE-EPI) sequences and to compare liver stiffness (LS) values between the sequences during expiratory and inspiratory phases in patients with chronic liver disease or liver cirrhosis.Methods: One hundred and eight patients who underwent MRE were included in this retrospective study. MRE was performed at 3 T based on both sequences during expiration as well as inspiration. Technical failure of MRE was determined if there was no pixel value with a confidence index higher than 95% and/or no apparent shear waves imaged. LS measurements were performed using free-drawing region of interest. To evaluate clinical factors related to the technical success rate of MRE, we assessed etiology of liver disease, ascites, body habitus, iron deposition, and liver morphology of patients. Statistical analysis was performed with the Wilcoxon test, Bland-Altman plot, independent t test, Mann-Whitney test, and McNemar test.Results: The technical success rate of MRE in SE-EPI was significantly higher than that of GRE (98.1% vs. 80.7%, p < 0.0001). On the basis of univariate analysis, height, weight, and BMI were significantly associated with failure of MRE (p < 0.05). There was no significant difference in LS values between GRE and SE-EPI (2.82 kPa vs. 2.92 kPa (p > 0.05)). However, the LS values were significantly higher during inspiration than expiration with both GRE and SE-EPI (p < 0.0001).Conclusion: MRE in SE-EPI during expiratory breath-hold can be used as a reliable examination to evaluate liver fibrosis.Key Points: • The technical success rate of MR elastography in spin-echo echo-planar imaging (SE-EPI) was significantly higher than that in gradient-recalled echo (GRE) during both the inspiratory and expiratory phases. • Liver stiffness values were significantly higher during inspiration than during expiration in both GRE and SE-EPI. • MR elastography in SE-EPI during expiratory breath-hold can be used as a reliable examination in patients with liver fibrosis.
      pubtype: Academic Journal
      doctype:
        diagnostic images
        research
        tables/charts
        Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N