ZTE MR-based attenuation correction in brain FDG-PET/MR: performance in patients with cognitive impairment.

Objective: One of the main challenges of integrated PET/MR is to achieve an accurate PET attenuation correction (AC), especially in brain acquisition. Here, we evaluated an AC method based on zero echo time (ZTE) MRI, comparing it with the single-atlas AC method and CT-based AC, set as reference.Met...

Descripción completa

Detalles Bibliográficos
Publicado en:European Radiology Vol. 30; no. 3; pp. 1770 - 1780
Autores principales: Sgard, Brian, Khalifé, Maya, Bouchut, Arthur, Fernandez, Brice, Soret, Marine, Giron, Alain, Zaslavsky, Clara, Delso, Gaspar, Habert, Marie-Odile, Kas, Aurélie
Formato: Journal Article
Publicado: Springer Nature 2020
Acceso en línea:Ver este registro en EBSCOhost
fields @attributes:
  recordID: 1
pdfLink:
plink: https://search.ebscohost.com/login.aspx?direct=true&db=ccm&AN=148390825&site=ehost-live
header:
  @attributes:
    shortDbName: ccm
    uiTerm: 148390825
    longDbName: CINAHL Complete
    uiTag: AN
  controlInfo:
    bkinfo:
    dissinfo:
    jinfo:
      jid:
        09387994
        NPH
      jtl: European Radiology
      issn: 09387994
      maglogo: N
    pubinfo:
      dt: 2020
      vid: 30
      iid: 3
      pid: 237
      pub: Springer Nature
      place: New York, New York
    artinfo:
      ui:
        148390825
        148390825
        NLM31748857
        10.1007/s00330-019-06514-z
        NLM31748857
        148390825
      ppf: 1770
      ppct: 10
      formats:
        fmt:
          – @attributes:
              type: T
          – @attributes:
              type: P
      tig:
        atl: ZTE MR-based attenuation correction in brain FDG-PET/MR: performance in patients with cognitive impairment.
      aug:
        au:
          Sgard, Brian
          Khalifé, Maya
          Bouchut, Arthur
          Fernandez, Brice
          Soret, Marine
          Giron, Alain
          Zaslavsky, Clara
          Delso, Gaspar
          Habert, Marie-Odile
          Kas, Aurélie
        affil: Department of Nuclear Medicine, Groupe Hospitalier Pitié-Salpêtrière Charles Foix, 75013, APHP, Paris, France
      sug:
        subj:
          Fludeoxyglucose F 18 Pharmacodynamics
          Brain
          Magnetic Resonance Imaging Methods
          Tomography, Emission-Computed Methods
          Diagnostic Imaging Methods
          Aged
          Aged, 80 and Over
          Middle Age
          Female
          Adult
          Male
          Impact of Events Scale
          Aged: 65+ years
          Aged, 80 & over
          Middle Aged: 45-64 years
          Adult: 19-44 years
          Female
          Male
      ab: Objective: One of the main challenges of integrated PET/MR is to achieve an accurate PET attenuation correction (AC), especially in brain acquisition. Here, we evaluated an AC method based on zero echo time (ZTE) MRI, comparing it with the single-atlas AC method and CT-based AC, set as reference.Methods: Fifty patients (70 ± 11 years old, 28 men) underwent FDG-PET/MR examination (SIGNA PET/MR 3.0 T, GE Healthcare) as part of the investigation of suspected dementia. They all had brain computed tomography (CT), 2-point LAVA-flex MRI (for atlas-based AC), and ZTE-MRI. Two AC methods were compared with CT-based AC (CTAC): one based on a single atlas, one based on ZTE segmentation. Impact on brain metabolism was evaluated using voxel and volumes of interest-based analyses. The impact of AC was also evaluated through comparisons between two subgroups of patients extracted from the whole population: 15 patients with mild cognitive impairment and normal metabolic pattern, and 22 others with metabolic pattern suggestive of Alzheimer disease, using SPM12 software.Results: ZTE-AC yielded a lower bias (3.6 ± 3.2%) than the atlas method (4.5 ± 6.1%) and lowest interindividual (4.6% versus 6.8%) and inter-regional (1.4% versus 2.6%) variabilities. Atlas-AC resulted in metabolism overestimation in cortical regions near the vertex and cerebellum underestimation. ZTE-AC yielded a moderate metabolic underestimation mainly in the occipital cortex and cerebellum. Voxel-wise comparison between the two subgroups of patients showed that significant difference clusters had a slightly smaller size but similar locations with PET images corrected with ZTE-AC compared with those corrected with CT, whereas atlas-AC images showed a notable reduction of significant voxels.Conclusion: ZTE-AC performed better than atlas-AC in detecting pathologic areas in suspected neurodegenerative dementia.Key Points: • The ZTE-based AC improved the accuracy of the metabolism quantification in PET compared with the atlas-AC method. • The overall uptake bias was 21% lower when using ZTE-based AC compared with the atlas-AC method. • ZTE-AC performed better than atlas-AC in detecting pathologic areas in suspected neurodegenerative dementia.
      pubtype: Academic Journal
      doctype: Journal Article
      ougenre: Article
    language: English
    refInfo:
    holdings:
      @attributes:
        islocal: N