Improvement of the diagnostic accuracy for intracranial haemorrhage using deep learning–based computer-assisted detection.

Purpose: To elucidate the effect of deep learning–based computer-assisted detection (CAD) on the performance of different-level physicians in detecting intracranial haemorrhage using CT. Methods: A total of 40 head CT datasets (normal, 16; haemorrhagic, 24) were evaluated by 15 physicians (5 board-c...

Descripción completa

Detalles Bibliográficos
Publicado en:Neuroradiology Vol. 63; no. 5; pp. 713 - 721
Autores principales: Watanabe, Yoshiyuki, Tanaka, Takahiro, Nishida, Atsushi, Takahashi, Hiroto, Fujiwara, Masahiro, Fujiwara, Takuya, Arisawa, Atsuko, Yano, Hiroki, Tomiyama, Noriyuki, Nakamura, Hajime, Todo, Kenichi, Yoshiya, Kazuhisa
Formato: diagnostic images research tables/charts Journal Article
Publicado: Springer Nature May2021
Acceso en línea:Ver este registro en EBSCOhost
Descripción
Sumario:Purpose: To elucidate the effect of deep learning–based computer-assisted detection (CAD) on the performance of different-level physicians in detecting intracranial haemorrhage using CT. Methods: A total of 40 head CT datasets (normal, 16; haemorrhagic, 24) were evaluated by 15 physicians (5 board-certificated radiologists, 5 radiology residents, and 5 medical interns). The physicians attended 2 reading sessions without and with CAD. All physicians annotated the haemorrhagic regions with a degree of confidence, and the reading time was recorded in each case. Our CAD system was developed using 433 patients' head CT images (normal, 203; haemorrhagic, 230), and haemorrhage rates were displayed as corresponding probability heat maps using U-Net and a machine learning–based false-positive removal method. Sensitivity, specificity, accuracy, and figure of merit (FOM) were calculated based on the annotations and confidence levels. Results: In patient-based evaluation, the mean accuracy of all physicians significantly increased from 83.7 to 89.7% (p < 0.001) after using CAD. Additionally, accuracies of board-certificated radiologists, radiology residents, and interns were 92.5, 82.5, and 76.0% without CAD and 97.5, 90.5, and 81.0% with CAD, respectively. The mean FOM of all physicians increased from 0.78 to 0.82 (p = 0.004) after using CAD. The reading time was significantly lower when CAD (43 s) was used than when it was not (68 s, p < 0.001) for all physicians. Conclusion: The CAD system developed using deep learning significantly improved the diagnostic performance and reduced the reading time among all physicians in detecting intracranial haemorrhage.